Pilot's Operating Handbook
Section 7
Description
Edition 0 - October 31, 2013
Rev. 5
Page 7.3.3
>> Without v15.11 GARMIN software and voice alerts (Pre-MOD70-0407-00D).
General alarms warning lights and CAS messages
WARNING
and
CAUTION
messages appear on the MFD CAS window to alert
crew about monitored systems discrepancies. As a message appears, a chime is
heard. Refer to the GARMIN Pilot's Guide to know all possible CAS messages.
A
MASTER WARNING
red flashing indicator and a
MASTER CAUTION
amber
indicator located on instrument panel - see figure 7.3.8, in front of the pilot, illuminate
as soon as one or several messages of same color light on.
To cancel and reset a general alarm, press on the red or amber indicator. A pressure
on the red indicator also stops red message associated aural tones.
Aural warnings
- see figure 7.3.2
The aural warnings are intended to alert the pilot during some configurations. The
aural signals are heard through the loud-speakers or the buzzer installed in cockpit
overhead panel.
The aural warnings consist of :
-
the aural warning box,
-
the buzzer and loud-speakers.
The system uses :
-
the stall warning horn,
-
the VMO alarm,
-
the landing gear control unit,
-
the flap geared motor.
Aural warning box
The aural warning box consists of a box including logic circuits, which create the
signals heard in the aural warning loud-speakers.
According to the airplane configuration, different signals are produced by the logic
circuits :
-
gear up and idle
high-pitched sound
-
gear up and extended flaps
high-pitched sound
-
stall
low-pitched sound