Apr. 2007
7
-21
DSC48
4.2.4 OPERATION OF AUTOMATIC
FEEDING DEPTH CONTROL LAMP
The automatic feeding depth control lamp is automatically
turned on by the automatic feeding depth selection switch.
This lamp is turned off if the manual switch is operated. If
an error 1 is generated during self-diagnosis, it blinks.
4.2.5 OUTPUT STOP OF SHALLOW AND
DEEP FEEDING MOTORS
When the feeding chain reaches the shallowest or deepest
feeding position, the limit switch turns OFF (normally ON)
and stops the relay which cuts power to the feeding depth
control relay. Then, power will not be supplied to the feed-
ing depth control motor.
4.2.6 MOTOR PROTECTION
If the feeding depth control relay's output in the threshing
controller is sent out 60 times consecutively to one direc-
tion, outputting to the direction is restricted. This restriction
is cancelled when the output is sent to the opposite direc-
tion or when the grain sensor S1 is ON and the S2 is OFF.
(1) Threshing
controller
417W759A
(1) Feeding depth control motor
417W722A
Summary of Contents for DSC48
Page 1: ...DSC48 COMBINE HARVESTER WORKSHOP MANUAL...
Page 2: ......
Page 4: ......
Page 6: ......
Page 8: ......
Page 38: ...MEMO...
Page 40: ......
Page 106: ......
Page 136: ...MEMO...
Page 138: ......
Page 140: ......
Page 160: ...MEMO...
Page 162: ......
Page 196: ...MEMO...
Page 198: ......
Page 216: ......
Page 251: ...Apr 2007 7 11 DSC48 2 3 WIRING DIAGRAM 417W717A...
Page 262: ...7 22 Apr 2007 DSC48 4 3 WIRING DIAGRAM 417W723A...
Page 281: ...417W758B B ON GND B GND 7 2 CIRCUIT DIAGRAM Apr 2007 7 41 DSC48...
Page 282: ......
Page 285: ...DSC48 INDEX...