5
-16
Apr. 2007
DSC48
F. BATTERY CABLE
(Check every 50 hours)
1. When replenishing the battery with electrolyte, use dis-
tilled water and do not over
fi
ll.
2. Use only the speci
fi
ed battery.
3. When disconnecting the battery cables, disconnect
the negative (ground) cable
fi
rst. When connecting the
cables, connect the positive cable
fi
rst.
417W537A
(1) Battery
(3) Positive
cable
(2) Negative
cable
G. AIR CLEANER ELEMENT
(Check every 50 hours and replace every 300 hours)
• Before daily operation, remove any dust by blowing air
from the inside of element or tapping it lightly. (When
using compressed air, its pressure should not exceed 5
kgf/cm
2
.)
417W538A
(1) Air cleaner
(2) Wing bolt
H. CLEANING AIR FILTER
1. When dust is accumulated over the mark on the side of
the air
fi
lter, remove the wing nut and remove the dust
as shown in the
fi
gure.
417W539A
(1) Air
fi
lter
(3) Dust
(2) Wing
nut