Use the key “1” for the orientation of the in
-
terface panel as described in par 2.2.2. If the
key is lost or damaged, the operation can be
done using a standard 2mm allen wrench.
Once the 2 plastic keys have been separat
-
ed they can be used by inserting “2” in one
of the holes “B” in key “3”: whichever hole is
most convenient, depending on the opera
-
tion. At this point you obtain a multifunction
cross key, with a use corresponding to each
of the 4 ends.
Figure 22
A
C
D
B
F
2
1
3
E
To use the cross key you must put the unused key “1” away in a
safe place so that it does not get lost, or else put it back in its seat
inside key “3” at the end of operations.
Use of end “C”:
this is practically a straight tip screwdriver of the correct size for manoeu
-
vring the caps of the main connections of the system (1” and 1”1/4). To
be used at the first installation to remove the caps from the mouths on
which you want to connect the
system; for the filling operation in
the case of horizontal installation;
to access the non-return valve,
… If the key is lost or damaged,
the same operations can be per
-
formed using a straight tip screw
-
driver of a suitable size
.
Use of end “D”:
hexagonal socket head suitable for re
-
moving the cap to perform filling in the
case of vertical installation. If the key is
lost or damaged, the same.
Figure 23
Figure 24
Figura 25
Summary of Contents for E.sybox 30
Page 6: ......
Page 59: ...ITALIANO IT 56 ...
Page 62: ......
Page 116: ......
Page 172: ......
Page 228: ......
Page 284: ......
Page 340: ......
Page 394: ......
Page 448: ......
Page 501: ...ROMÂNĂ RO 498 ...
Page 504: ......
Page 560: ......
Page 616: ......
Page 669: ...TÜRKÇE TR 666 ...
Page 672: ......
Page 728: ......
Page 781: ...ČESKY CZ 778 ...
Page 784: ......
Page 838: ......
Page 889: ......
Page 906: ...903 فارسی ...