Response messages
(1). “
Success.
”
When users input a value that is a multiple of 64 and the setting is successful.
(2). "
Fail !
Trunk member port %-p can not be configured because the master is not contained in the portlist" .
The configured portlist contains trunk port but not it’s master port.
(3). "
Success,
The setting value is not a multiple of 64, closest value %d is chosen
".
If a user inputs a value that is not a multiple of 64 (or whatever bandwidth increment is used for the
chip). The token value becomes the effective limit. The Token value is set at the nearest multiple of
the bandwidth increment is used for the chip (i.e. 32 Kbits, 64 Kbits, etc.) without exceeding the
specified limit. For example, a user inputs a limit of 130, therefore the Token value will be 128.
43-2 show bandwidth_control
Purpose
Used to display the port bandwidth control table.
Format
show bandwidth_control {<portlist>}
Description
The
show bandwidth_control
command displays the port bandwidth configurations.
Parameters
Parameters
Description
portlist
Specifies a range of ports to be displayed.
If no parameter is specified, the system will display all port bandwidth
configurations.
Restrictions
None.
Examples
To display the port bandwidth control table: