4. Change the Management VLAN to VLAN 10 and set Port 24 to Trunk mode
Switch Management>VLAN Configuration>IEEE 802.1q Tag VLAN>Management VLAN
Click
“OK” to apply the settings.
5. Check Management VLAN 10 settings again.
Switch Management>VLAN Configuration>IEEE 802.1q Tag VLAN>Configure VLAN
Now, Port 24 and CPU are member ports in Management VLAN 10.
Treatments of Packets:
1. A tagged packet arrives at Port 24
In this example, port 24 is assigned as a management port. Therefore, the client can
manage the Managed Switch remotely. When management traffic with tag 10 arrives at
port 24, the tag will be removed. Then, untagged traffic is sent to CPU. When sending
out management traffic out from port 24, it will be added a tag 10.
Change CPU VLAN ID to 10
Select
“Trunk”