MAINTENANCE WITH Q&A
Page 5-17
WATER QUALITY
Puri
fi
ed water is recommended for use with our humidity systems. Water
should be provided within 0.05 to 2M (.25 to 10ppm) DI and <2mg/L of
free chlorine, Distilled water or Reverse Osmosis (RO) water outside of
these limits may cause either corrosion or scaling. Tap water may be
used with our optional Demineralizer Filtration System. A Recirculation
Humidity Water Supply System is also available. Inlet water pressure
should not exceed 10psi for use with an atomizer or 25 psi for use with
a boiler. For optimal use of the atomizer and boiler systems, inlet water
pressure should not fall below 10 PSI (69 kPa) for both boilers and
atomizers. A Water Pressure Regulator must be used.
Water speci
fi
cation 0.05 to 2 Mega
OHMS in addition to <2mg/L of free
chlorine.
CAUTION
Failure to maintain cartridge may
result in chloride corrosion of
stainless steel interior surfaces
which is not covered under
warranty.
WARNING
!
!
Maximum water inlet pressure is
10 PSI (170 kPa) for an atomizer
and 25 PS (274 kPa)I for a boiler.
Exceeding this pressure may
cause catastrophic failure of the
fi
lter housing. For optimal use of
the atomizer and boiler systems,
inlet water pressure should not
fall below 10 PSI (69 kPa) for both
boilers and atomizers.
WARNING
!
Summary of Contents for ZP 16
Page 1: ...Installation Operation Maintenance Manual ZP Series 56120 REV AH 10 2019...
Page 4: ...INTRODUCTION THIS PAGE INTENTIONALLY LEFT BLANK...
Page 6: ...CHAMBER LABELS MEANINGS THIS PAGE INTENTIONALLY LEFT BLANK...
Page 40: ...GENERAL DESCRIPTION Page 2 24 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 42: ...INSTALLATION Page 3 2 Figure 1 Transporting a Chamber...
Page 46: ...INSTALLATION Page 3 6 Table 2 Water Usage SI Units...
Page 62: ...OPERATION Page 4 14 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 82: ...MAINTENANCE WITH Q A Page 5 20 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 84: ...SERVICE PARTS WARRANTY Page 6 2 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 88: ...SYSTEM DIAGRAMS Page 9 4 THIS PAGE INTENTIONALLY LEFT BLANK...