Crystal Vision
Installation
TANDEM-110 User Manual R1.8
78
07/07/2010
GPI Functions Op=open, Cl=closed (connect to ground)
Pre-set
0 1 2 3 4 5 6 7 8 9 10
11
12
13
14
15
‘a’
Op Cl Op Cl Op Cl Op Cl Op Cl Op Cl Op Cl Op Cl
‘b’
Op Op Cl Cl Op Op Cl Cl Op Op Cl Cl Op Op Cl Cl
‘c’
Op Op Op Op Cl Cl Cl Cl Op Op Op Op Cl Cl Cl Cl
'd'
Op Op Op Op Op Op Op Op Cl Cl Cl Cl Cl Cl Cl Cl
2U Indigo and FR2AV GPI Connections
GPI lines 1 to 6 of each TANDEM card are brought to one of the four remote connectors
at the rear of the FR2AV frame as follows:
Slot
no.
GPI 1
pin rem
GPI 2
pin rem
GPI 3
pin rem
GPI 4
pin rem
GPI 5
pin rem
GPI 6
pin rem
1
8 1 9 1 18 1 26 1 19 2 20 2
2
7 1 16 1 17 1 25 1 10 2 11 2
3
8 3 9 3 18 3 26 3 19 4 20 4
4
7 3 16 3 17 3 25 3 10 4 11 4
5
5 1 6 1 15 1 24 1 1 2 2 2
6
4 1 14 1 13 1 23 1 3 2 4 2
7
5 3 6 3 15 3 24 3 1 4 2 4
8
4 3 14 3 13 3 23 3 3 4 4 4
9
3 1 12 1 22 1 21 1 12 2 13 2
10
10 1 11 1 19 1 20 1 21 2 22 2
11
3 3 12 3 22 3 21 3 12 4 13 4
12
10 3 11 3 19 3 20 3 21 4 22 4
Note:
Remote (rem) 1 and Remote (rem) 3 are 26 way high density ‘D’ type female sockets
and frame ground is pin 2 in each case. Remote (rem) 2 and Remote (rem) 4 are 26 way
high density ‘D’ type male plugs and frame ground is pin 6 in each case.
.1U Indigo and FR1AV GPI connections
GPI lines ‘a’ to ‘f’ of each TANDEM card connect to one of two rear remote connectors
as follows:
Slot no.
‘a’ pin
‘b’ pin
‘c’ pin
‘d’ pin
‘e’ pin
‘f’ pin
1
8 (1)
9 (1)
18 (1)
26 (1)
19 (2)
20 (2)
2
7 (1)
16 (1)
17 (1)
25 (1)
10 (2)
11 (2)
3
5 (1)
6 (1)
15 (1)
24 (1)
1 (2)
2 (2)
4
4 (1)
14 (1)
13 (1)
23 (1)
3 (2)
4 (2)
5
3 (1)
12 (1)
22 (1)
21 (1)
12 (2)
13 (2)
6
10 (1)
11 (1)
19 (1)
20 (1)
21 (2)
22 (2)
Table shows pin number (Remote number)
Notes:
Remote 1: 26 way high density D-type socket. GND is pin 2 and +5V @500mA is pin 1.
Remote 2: 26 way high density D-type plug. GND is pin 6 and +5V @500mA is pin 15.