35
Peristaltic Pumps Series IP 100-800
1. Switch off the pump and secure it against
restarting.
2. Drain off the lubricating fluid (see chapter 5.8.1)
3. Remove pump cover with O-ring.
4. Turn the rotor by hand until one sliding shoe
is free.
5. Then the shims (Fig. 45) must be removed to
reduce the pumping pressure or additional
shims must be added to increase the
pumping pressure. If shims are changed, you
must make sure that both sliding pieces are
changed to the same dimension. The
measurements must comply exactly with the
table (see below).
6. Fasten the pump cover again with O-ring
(see chapter 5.8.3).
7. Replace oil chain plug.
8. Fill in lubricating fluid.
9. Replace fill plug.
Pressure
Diameter - rotor
0 - 2 bar / 0-29 psi
338 mm / 13.31 inches
2 - 4 bar / 29-58 psi
339 mm / 13.35 inches
4 - 6 bar / 58-87 psi
340 mm / 13.39 inches
6 - 8 bar / 87-116 psi
341 mm / 13.43 inches
8 - 10 bar / 116-145 psi
342 mm / 13.46 inches
10-13 bar / 145-188,4 psi
343 mm / 13.50 inches
When changing the rotor
dimension use the same shims on
both sides.
5.10.1 Installation of a full fabric hose
Besides the operation with vacuum the pump
can also be operated with a pumping hose
without vacuum bore. The installation
procedure for a so-called full fabric hose is
identical with the procedure for a standard
pumping hose.
Switch off the pump and secure it against
restarting.
Then proceed as described in chapter 5.8.3.
1
Attention!
Fig. 45
1 Shim