24
Peristaltic Pumps Series IP 100-800
IP 200 Ø 30 mm - pumping hose
Pressure
Diameter - rotor
0 - 2 bar / 0-29 psi
154 mm / 6.06 inches
2 - 4 bar / 29-58 psi
154 mm / 6.06 inches
4 - 6 bar / 58-87 psi
156 mm / 6.14 inches
6 - 8 bar / 87-116 psi
158 mm / 6.22 inches
8 - 10 bar / 116-145 psi
158 mm / 6.22 inches
10-13 bar / 145-188,4 psi 160 mm / 6.30 inches
IP 200 Ø 25 mm - pumping hose
Pressure
Diameter - rotor
0 - 2 bar / 0-29 psi
154 mm / 6.06 inches
2 - 4 bar / 29-58 psi
154 mm / 6.06 inches
4 - 6 bar / 58-87 psi
156 mm / 6.14 inches
6 - 8 bar / 87-116 psi
158 mm / 6.22 inches
8 - 10 bar / 116-145 psi
158 mm / 6.22 inches
10-13 bar / 145-188,4 psi 160 mm / 6.30 inches
5.4.1
Installation of a full fabric hose
Besides the operation with vacuum the pump can
also be operated with a pumping hose without
vacuum bore. The installation procedure for a so-
called full fabric hose is identical with the
procedure for a standard pumping hose.
Switch off the pump and secure it against
restarting.
Then proceed as described in chapter 5.2.3.
Changing the rotor requires a new
pumping hose.
IP 100 Ø 15 mm - pumping hose
Pressure
Diameter - rotor
0 - 2 bar / 0-29 psi
153 mm / 6.02 inches
2 - 4 bar / 29-58 psi
153 mm / 6.02 inches
4 - 6 bar / 58-87 psi
156 mm / 6.14 inches
6 - 8 bar / 87-116 psi
156 mm / 6.14 inches
8 - 10 bar / 116-145 psi 160 mm / 6.30 inches
Attention!
Summary of Contents for ELRO IP 100