19
Peristaltic Pumps Series IP 100-800
4.3
Taking out of service
Strictly observe the safety
regulations in chapter 2 of these
instructions.
The shut-down procedure for maintenance,
installation and cleaning work must only be
performed by authorized and trained personnel.
1. Switch off the electric power supply and
secure against unintended restarting.
2. Close shut-off valves on suction and pressure
side.
3. Relieve the pressure in suction and pressure
lines.
Fluids escaping under pressure can
cause severe injury.
Take care when loosening pressure
fittings; wear protective clothing.
Be extremely careful when handling
hazardous fluids.
You should immediately consult a
doctor if you had contact with such
substances.
4. Loosen suction and pressure fittings carefully.
The system may still be under pressure or
tension.
5. Disconnect suction and pressure lines from
the pump and disassemble the rinsing line (if
present).
6. If worn parts are detected when inspecting the
pump, the respective parts must be replaced.
5.
Maintenance
Always observe the safety
regulations in chapter 2 when
performing maintenance work and
conversions!
Check all lines and fittings regularly for leaks
and externally visible damage!
Eliminate any faults immediately!
Peristaltic pumps of series IP require only little
maintenance. Ball bearings and radial seals in
the pump neck are lifetime lubricated by the
silicone oil or glycerine filling.
The drive must be serviced according to the
instructions of the respective manufacturer.
The pumping hose is the only wear item on the
pump.
Pumps with electric drive must be
switched off and disconnected
from the electric power supply
before starting maintenance work!
If the pump is used for aggressive,
caustic or toxic media, the pump
must be flushed with a neutralizing
agent before opening the pump
housing.
5.1
Cleaning
General notes:
Always wear protective clothing
when working with solvents or
cleansing agents.
Housing, cooling fins, openings and covers on
equipment components are very often not just
protections, but have additional functions such
as cooling, insulation, noise reduction, splash
protection, etc.
Attention!
Attention!
Attention!
Hazard!
Caution!