K A - B A N D T W T A O D U A M P L I F I E R
TYPICAL MENU TREE E-4
Installation and Operation Manual,
Doc. 01031492 Rev. 3
L R
LOWER LINE SHOWS:
ATTEN: NN.N dBm CABINET: NNN C TUBE: NNN C
FAN CTRL: N.N V
U
D
AMP
FAULT CONDITION
LOWER LINE SHOWS:
“HELIX OVER CURRENT FAULT”
“HELIX OVER VOLTAGE FAULT”
“HELIX UNDER VOLTAGE FAULT”
“POWER SUPPLY ARC FAULT”
“DC BUSS FAULT”
“FAN STALLED FAULT”
“HIGH REFLECTED RF FAULT”
“LOW RF FAULT”
“HIGH RF FAULT”
“BBRAM DATA INVALID FAULT”
“SSIPA OVER CURRENT FAULT”
“HELIX VOLTAGE DETECTED DURING STANDBY”
“TUBE OVER TEMPERATURE FAULT”
“CABINET OVER TEMPERATUE FAULT”
“COVER INTERLOCK FAULT”
“TUBE SWITCH OVER TEMP FAULT”
“EXTERNAL INTERLOCK FAULT”
ALARM CONDITION
LOWER LINE SHOWS:
If a fault conditions occurs,
the Main menu will
automatically be displayed.
SYSTEM
DISPLAY
A1: XMIT NN.N dBm MANUAL ON-line
1:1 System
DISPLAY
A1: XMIT NN.N dBm ON-line A2: FLT NN.N dBm OFF-line
1:2 System
A3: XMIT NN.N dBm ON-line MANUAL
A2: XMIT NN.NN dBm MANUAL OFF-line
DISPLAY
A1: XMIT NN.N dBm LOAD MANUAL
1:1 Power Combined System
A2: XMIT NN.N dBm OUT MANUAL
A1: MANUAL ON-line
A2: MANUAL OFF-line
A1: ON-line A2: OFF-line
A3: MANUAL ON-line
A1: XMIT NN.N dBm LOAD MANUAL
A2: XMIT NN.N dBm OUT MANUAL
A2: OUT MANUAL
A1: LOAD MANUAL SW1:2 SW2:1 SW3:2
SYSTEM
SYSTEM
SYSTEM
CONTROL
SET PWR
ENTER
TO SELECT
U
D
ENTER
TO ADJUST TO ACCEPT
CHANGE
CIF CONTROL POINT:
DISPLAY
LOCAL
SERIAL ETHERNET
REPEAT PRESSING CONTROL KEY TO CYCLE
BETWEEN LOCAL/SERIAL/ETHERNET
t
AMP/SYSTEM/CONTROL/SET PWR
FUNCTION KEY TREE
AMP
SYSTEM
LCL
M&C
RESET
MENU
FAULT