60
MYDENS
COSMOGAS
7 - USE
Parameter
Description of the parameter
Access
level
U.M.
Range
Factory
value
Customised
values
2112
Central heating negative hysteresis
Factory
°C
0...20
5
2113
Maximum power in DHW mode
Installer
%
50...100
100
2114
Minimum power in DHW mode
Installer
%
1...30
1
2115
DHW puffer temperature setting
Installer
°C
20...80
50
2116
Programmable input J7 2-3
Central heating pressure sensor
Installer
#
0 = Disabled
1 = Enable;
2 = N/A;
3 = N/A;
1
2117
Programmable input J7 7-8
Water flow sensor
Installer
#
0 = Disabled
1 = DHW flow
2 = Instantaneous DHW
thermostat
3 = Water flow
4 = N/A
1
2118
Programmable input J7 9-10
Installer
#
0 = Disabled
2 = N/A;
0
2120
Programmable input J6 3-10
Return temperature sensor
Installer
#
0 = Disabled
1 = Enable;
1
2121
Programmable input J6 5-12
Flue gas temperature sensor
Installer
#
0 = Disabled
1 = Enable;
2 = N/A;
1
2122
Programmable input J6 6-13
Cascade temperature sensor
Installer
#
0 = Disabled
1 = N/A;
3 = Enable;
3
2123
Programmable input J7 2-4
Installer
#
0 = Disabled
1 = N/A;
3 - 6 = N/A;
0
2124
Room thermostat programmable input
Installer
#
0 = Disabled
1 = Enable;
1
2125
Programmable output 1 J3 3-8
Installer
#
0 = Disabled
1-5 = N/A;
6 = Alarm;
7 = Automatic filling;
0
2126
Programmable output 2 J3 5-10
Factory
#
0 = Disabled
1-8 = N/A;
9 = Spark generator
10 = N/A;
9
2127
Programmable output 3 J3 6
Installer
#
0 = Disabled
1-10 = N/A;
0
2128
Output setting 3-way valve
Installer
#
0 = Disabled
1-17 = N/A;
18 = DHW in stand by;
19 = N/A;
20 = Central heating in stand by;
20
2129
Domestic hot water flow rate sensor
Installer
#
0 = Bitron;
1 = Huba DN8;
2 = Huba DN10;
3 = Huba DN15;
4 = Huba DN20;
5 = N/A;
0