32
MYDENS
COSMOGAS
5 - INSTALLATION
5.17.4 - “Split 80/80PP” system:
installation examples
In Figure 29 two installation examples are seen:
Exhaust in chimney with condensate collection inside the
appliance itself.
The horizontal part of the flue exhaust side must be inclined
towards the appliance.
The air intake must slope towards the outside to prevent
rain water entering.
Exhaust on the outside, directly via the appliance ducts with
condensate collection inside the appliance itself.
The air intake must slope towards the outside to prevent
rain water entering.
Figure 29
In Figure 30 you can see an example of a separated
flue exhaust set-up, where the exhaust is made from a
polypropylene hose for piping the technical cells.
The condensate produced in the vertical duct must all be
conveyed into the appliance.
The air intake must slope towards the outside to prevent
rain water entering.