Bonnet OPTIMUM 700 Builder’S Specifications Download Page 1

 

OPTIMUM 700 & 900

 

 

GAS & ELECTRIC

 

 

BOILING PANS

 

 

BUILDER’S SPECIFICATIONS 

 

 

Part A: Technical characteristics

 

Part B: Technical instructions for the installer

 

 

WARNING

 

 Installation and repairs must be carried out by personnel approved by the manufacturer and in 

accordance with current regulations and standards. 

 If any modifications are made the manufacturer can accept no responsibility whatsoever. 

 These appliances must be used in a well-ventilated area. 

 Read the notice carefully before installation. 

 

 When handling it, it is imperative to leave the appliance on its base till final installation.. 

 

 
 

 

 

3BE390582NI

 

 

9

Summary of Contents for OPTIMUM 700

Page 1: ...out by personnel approved by the manufacturer and in accordance with current regulations and standards If any modifications are made the manufacturer can accept no responsibility whatsoever These appliances must be used in a well ventilated area Read the notice carefully before installation When handling it it is imperative to leave the appliance on its base till final installation 3BE390582NI 9 ...

Page 2: ... THE COMPONENTS LOCATED BEHIND THE UPPER TRIMMING 21 2 6 ACCESS TO THE COMPONENTS LOCATED BEHIND THE LOWER TRIMMING 21 3 INSTALLATION PUTTING IN PLACE 22 3 1 ASSEMBLY OF CANTILEVER APPLIANCES TO A WALL 22 3 2 ASSEMBLY OF APPLIANCES ON INDIVIDUAL BASE 25 3 3 ASSEMBLY OF APPLIANCES ON A MASONRY BASE 26 4 INSTALLATION CONNECTIONS 28 4 1 ELECTRIC CONNECTION 22 4 2 GAS CONNECTION 30 4 3 WATER CONNECTIO...

Page 3: ...20 Natural gas 20 mbar m3 h 1 17 G25 Natural gas 20 25 mbar m3 h 1 33 ELECTRICITY Voltage Single phase 230Va c Power kW 0 1 HOT WATER Pressure 2 5 6 bars Maximum temperature 60 C Connection Hose 15 21 1 2 COLD WATER Pressure 2 5 6 bars Connection Hose 15 21 1 2 GUTTER 550 x 400 Mini TYPE OF APPLIANCE Back to the wall or another appliance GAS CONNECTION Gas outlet at 180 mm above the floor thread 1...

Page 4: ...bar m3 h 1 33 ELECTRICITY Voltage Single phase 230Va c Power kW 0 1 HOT WATER Pressure Max temperature 2 5 6 bars 60 C Connection Hose 15 21 1 2 COLD WATER Pressure 2 5 6 bars Connection Hose 15 21 1 2 SOFTENED WATER Pressure Water hardness 2 5 6 bars 70ppm Connection 20 27 3 4 GUTTER 550 x 400 Minimum TYPE OF APPLIANCE Back to a wall or another appliance GAS CONNECTION Gas outlet at 180 mm above ...

Page 5: ... phase 230V T or 400V N T Power kW 230V 3a c 8 400V 3Na c 8 Max intensity A 230V 3a c 20 1 400V 3Na c 11 5 HOT WATER Pressure 2 5 6 bars Max temperature 60 C Connection Hose 15 21 1 2 COLD WATER Pressure 2 5 6 bars Connection Hose 15 21 1 2 SOFTENED WATER Pressure 2 5 6 bars Water hardness 70ppm Connection 20 27 3 4 GUTTER 550 x 400 Mini TYPE OF APPLIANCE Back to a wall or another appliance ELECTR...

Page 6: ...ral gas 20 mbar m3 h 1 17 G25 Natural gas 20 25 mbar m3 h 1 33 ELECTRICITY Voltage Single phase 230Va c Power kW 0 1 HOT WATER Pressure 2 5 6 bars Maximum temperature 60 C Connection 20 27 3 4 COLD WATER Pressure 2 5 6 bars Connection 20 27 3 4 GUTTER 550 x 400 Mini TYPE OF APPLIANCE Back to the wall or another appliance GAS CONNECTION Gas outlet at 180 mm above the floor Thread 15 21 mm As standa...

Page 7: ...bar m3 h 1 33 ELECTRICITY Voltage Single phase 230Va c Power kW 0 1 HOT WATER Pressure Maximum temperature 2 5 6 bars 60 C Connection 20 27 3 4 HOT WATER Pressure 2 5 6 bars Connection 20 27 3 4 SOFTENED WATER Pressure Water hardness 2 5 6 bars 70ppm Connection 20 27 3 4 GUTTER 550 x 400 Mini TYPE OF APPLIANCE Back to the wall or another appliance GAS CONNECTION Gas outlet at 180 mm above the floo...

Page 8: ...r m3 h 2 27 G25 Natural gas 20 mbar m3 h 2 64 G25 Natural gas 25 mbar m3 h 2 46 ELECTRICITY Voltage Single phase 230Va c Power kW 0 1 HOT WATER Pressure 2 5 6 bars Maximum temperature 60 C Connection 20 27 3 4 COLD WATER Pressure 2 5 6 bars Connection 20 27 3 4 GUTTER 550 x 400 Mini TYPE OF APPLIANCE Back to the wall or another appliance GAS CONNECTION Gas outlet at 180 mm above the floor Thread 1...

Page 9: ...tural gas 25 mbar m3 h 2 46 ELECTRICITY Voltage Single phase 230Va c Power kW 0 1 HOT WATER Pressure Maximum temperature 2 5 6 bars 60 C Connection 20 27 3 4 COLD WATER Pressure 2 5 6 bars Connection 20 27 3 4 SOFTENED WATER Pressure Water hardness 2 5 6 bars 70ppm Connection 20 27 3 4 GUTTER 550 x 400 Mini TYPE OF APPLIANCE Back to the wall of another appliance GAS CONNECTION Gas outlet at 180 mm...

Page 10: ...r m3 h 2 27 G25 Natural gas 20 mbar m3 h 2 64 G25 Natural gas 25 mbar m3 h 2 46 ELECTRICITY Voltage Single phase 230Va c Power kW 0 1 HOT WATER Pressure Maximum temperature 2 5 6 bars 60 C Connection 20 27 3 4 COLD WATER Pressure 2 5 6 bars Connection 20 27 3 4 GUTTER 550 x 400 Mini TYPE OF APPLIANCE Back to the wall or another appliance GAS CONNECTION Gas outlet at 180 mm above the floor thread 1...

Page 11: ...tural gas 25 mbar m3 h 2 46 ELECTRICITY Voltage Single phase 230Va c Power kW 0 1 HOT WATER Pressure Maximum temperature 2 5 6 bars 60 C Connection 20 27 3 4 HOT WATER Pressure 2 5 6 bars Connection 20 27 3 4 SOFTENED WATER Pressure Water hardness 2 5 6 bars 70ppm Connection 20 27 3 4 GUTTER 550 x 400 Mini TYPE OF APPLIANCE Back to the wall or another appliance GAS CONNECTION Gas outlet at 180 mm ...

Page 12: ...mbar m3 h 3 01 G25 Natural gas 20 mbar m3 h 3 50 G25 Natural gas 25 mbar m3 h 3 15 ELECTRICITY Voltage Single phase 230Va c Power kW 0 1 HOT WATER Pressure Maximum temperature 2 5 6 bars 60 C Connection Hose 15 21 1 2 COLD WATER Pressure 2 5 6 bars Connection Hose 15 21 1 2 GUTTER 550 x 400 Mini TYPE OF APPLIANCE Back to the wall or another appliance GAS CONNECTION Gas outlet at 180 mm above the f...

Page 13: ...gas 25 mbar m3 h 3 15 ELECTRICITY Voltage Single phase 230Va c Power kW 0 1 HOT WATER Pressure x Maximum temperature 2 5 6 bars x 60 C Connection Hose 15 21 1 2 COLD WATER Pressure 2 5 6 bars Connection Hose 15 21 1 2 SOFTENED WATER Pressure x Water hardness 2 5 6 bars x 70ppm Connection Hose 15 21 1 2 GUTTER 550 x 400 Mini TYPE OF APPLIANCE Back to the wall or another appliance GAS CONNECTION Gas...

Page 14: ...CITY Three phase 230V T or 400V N T Power kW 230V 3a c 8 400V 3Na c 8 Max intensity A 230V 3a c 20 1 400V 3Na c 11 5 HOT WATER Pressure x Maximum temperature 2 5 6 bars x 60 C Connection 20 27 3 4 COLD WATER Pressure x Connection 2 5 6 bars x 20 27 3 4 SOFTENED WATER Pressure 2 5 6 bars Water harness 70ppm Connection 20 27 3 4 GUTTER 550 x 400 Mini TYPE OF APPLIANCE Back to the wall or another app...

Page 15: ... Depth x Height 900 x 1110 x 1250 WEIGHT KG ELECTRICITY Three phase 230V T or 400V N T Power kW 230V 3a c 15 400V 3Na c 15 Maximum intensity A 230V 3a c 37 7 400V 3Na c 21 7 HOT WATER Pressure 2 5 6 bars Maximum pressure 60 C Connection 20 27 3 4 COLD WATER Pressure 2 5 6 bars Connection 20 27 3 4 GUTTER 550 x 400 Mini TYPE OF APPLIANCE Back to the wall or another appliance ELECTRIC CONNECTION Ele...

Page 16: ...CTRICITY Three phase 230V T or 400V N T Power kW 230V 3a c 18 400V 3Na c 18 Max intensity maxi A 230V 3a c 45 2 400V 3Na c 26 1 HOT WATER Pressure Max temperature 2 5 6 bars 60 C Connection 20 27 3 4 COLD WATER Pressure 2 5 6 bars Connection 20 27 3 4 SOFTENED WATER Pressure 2 5 6 bars Water hardness 70ppm Connection 20 27 3 4 GUTTER 550 x 400 Mini TYPE OF APPLIANCE Back to the wall or another app...

Page 17: ... ELECTRICITY Three phase 230V T or 400V N T Power kW 230V 3a c 18 400V 3Na c 18 Max intensity A 230V 3a c 45 2 400V 3Na c 26 1 HOT WATER Pressure 2 5 6 bars Max temperature 60 C Connection 20 27 3 4 COLD WATER Pressure 2 5 6 bars Connection 20 27 3 4 SOFTENED WATER Pressure 2 5 6 bars Water hardness 70ppm Connection 20 27 3 4 GUTTER 550 x 400 Mini TYPE OF APPLIANCE Back to the wall of another appl...

Page 18: ...10 x 1200 WEIGHT KG ELECTRICITY Three phase 230V T or 400V N T Power kW 400V 3Na c 24 Max intensity A 400V 3Na c 34 7 HOT WATER Pressure 2 5 6 bars Max temperature 60 C Connection 20 27 3 4 COLD WATER Pressure 2 5 6 bars Connection 20 27 3 4 SOFTENED WATER Pressure Water hardness 2 5 6 bars 70ppm Connection 20 27 3 4 GUTTER 550 x 400 Mini TYPE OF APPLIANCE Back to the wall or another appliance ELE...

Page 19: ...he box marked with a cross indicates the gas for which the appliance has been adjusted A second plate is fixed near the nameplate which indicates The gas for which the appliance has been adjusted The country of destination Country of destination of the appliance IN CASE OF A CHANGE OF GAS See Section Changing the appliance from one gas to another Modify this plate and mention the new gas used Fill...

Page 20: ...RY Cedex Location of the plate Location of the plates 1 2 ELECTRIC BOILING PANS The firm plates are fixed on the control board see diagrams hereafter In any correspondence about your equipment please indicate The model number Model The serial number Fab Nr The date Date Firm plate Location of the plate Location of the plates ...

Page 21: ...units must only be placed against a wall or a partition The latter must be of non combustible materials or if not must be covered with an appropriate good insulating and non combustible material The manufacturer certifies that the packaging meets the provision 94 62 CE provision relating to packagings and packaging waste of 12 20 94 and requests that the final installer and user observes the rules...

Page 22: ...te It is not necessary to remove the water and electric control knobs Unscrew both M5 x 16 screws under the fascia 1 2 Tilt the fascia Pull it slightly downwards then to yourself Put the fascia in locking position clamp both lugs into the apertures foreseen in the fascia 2 6 ACCESS TO THE COMPONENTS PLACED BEHIND THE LOWER TRIMMING Unscrew both M5 x 16 screws under the lower trimming 1 2 Remove th...

Page 23: ...cket must support a tensile strength of 400 daN 2 brackets for a 400 800 1000 or 1200 wide appliance It is recommended for the fixation of cantilever appliances to a concrete wall to observe the following points The reinforced concrete of the wall must be at least of quality 23 MPA DTU Use HSA R M 8x75 plugs or equivalent 2 for cooking tops and 6 for cooking units For the plugs above each hole mus...

Page 24: ...al ducts a metal strengthener in the wall drill through the lower holes in the template Remove the template Increase the bracket fixation holes to diameter 8 and at least to 65 mm in depth Fix the brackets to the wall Use HSA R M 8x75 plugs or equivalent Open the brackets to the maximum by means of the centre screw Opened bracket Opening screw Set the appliances in place on the brackets and lock t...

Page 25: ...MORY Cedex Fix the appliances between themselves from behind in the way of collectors by one HM5 X 16 screw ø 5 flat washer Fix the appliances between themselves behind the front legs with a clamp a Place the clamp to the folded sides b Lock by hand c Complete tightening with the HM5 x 60 bolt Left appliance Right appliance ...

Page 26: ... OF APPLIANCES ON AN INDIVIDUAL BASE Fix the appliances between themselves at the back in the way of collectors with one HM5 X 16 screw Ø 5 flat washer Fix the appliances between themselves behind the legs with a clamp a Place the clamp to the folded sides b Lock by hand c Complete tightening with the HM5 x 60 bolt Left appliance Right appliance ...

Page 27: ...maximum slope 1 cm m maximum slope 1 cm m maximum slope Finished height with tiled front Finished height with tiled front Dimension of the base Range Am Depth of base as wall version Ac Depth of base as central version Ls Base length Finished height tiled on the front 700 520 1040 Lf 50 110 900 710 1420 Lf 50 110 The technical compartment is compulsory if the switch off tap the shut off valve or t...

Page 28: ...etween themselves at the front having removed the fascia see paragraph 3 4 with two HM5 X 16 screws Ø 5 flat washers Connect gas water and drainage lines to the appliances Fit the trimming plinths One front plinth per space 2000 base and one right and left end trimming plinth per stove depending on order Assemble one or more front plinths with junctions depending on the quantity of bases 2 screws ...

Page 29: ...wards the left Introduce the cable through the gland Tighten the gland Connect the wires Put the lug back in place Connect the equipotential link to the terminal foreseen for the purpose Only use supply cables of the H07 RN F type with 3 x 2 5 mm 2 section Foresee an omnipolar shut off device patented for safety of personnel with a distance between contacts of at least 3 mm when opened The install...

Page 30: ...ply cables of the H07 RN F type with following section Voltages MA BM 60 MA CD 110 MA BM 110 MA BM 150 MA BM 250 230 V 3 a c 4 x 4 mm2 4 x 6 mm2 4 x 10 mm2 4 x 10 mm2 400 V 3N a c 5 x 2 5 mm2 5 x 4 mm2 5 x 6 mm2 5 x 6 mm2 5 x 6 mm2 A means of shut off must be foreseen for fixed supply lines in compliance with the rules of installation The installation must meet the national rules in force France N...

Page 31: ...pply of the appliance it is necessary to connect a water column pressure gauge on a pressure tap placed on the gas unit gas pressure tap A on the diagram The gas pressure so measured must be equal to that indicated on the firm plate for the gas used See paragraph 1 Firm plate NOTE Connecting elbows with built in pressure tap One accessory is put at the installer s disposal under the reference no 1...

Page 32: ... boiling pan with direct heating 110 l boiling pan Bain marie Hot water Flexible hose 15 21 Flexible hose 15 21 20 27 20 27 Cold water Flexible hose 15 21 Flexible hose 15 21 20 27 20 27 Softened water 20 27 20 27 150 l boiling pan with direct heating 150 l boiling pan Bain marie 250 l boiling pan with direct heating Gas 250 l boiling pan Bain marie Electric 250 l boiling pan bain marie Hot water ...

Page 33: ...TRIES Countries Category Gas Pressure mbar Austria G 20 20 II2H3B P G 30 and G 31 50 Finland G 20 20 Sweden G 30 28 30 Denmark II2H3B P G 31 30 Belgium I2E G 20 G 25 20 25 I3 G 30 G 31 28 30 37 Germany G 20 20 G 25 20 II2ELL3B P G 30 G 31 50 I3P G 31 50 Spain United Kingdom G 20 20 Ireland Portugal Italy II2H3 G 30 G 31 28 30 37 Greece I2H G 20 20 Spain G 20 20 II2H3P G 31 50 France G 20 G 25 20 2...

Page 34: ...OUNTRIES Gas P mbar Gas P mbar CATEGORY NECESSARY AUTHORIZED OPERATIONS G 20 20 G 30 or G 31 50 CI RA Austria G 30 50 G 31 50 II2H3B P Nothing G 20 20 G 30 or G 31 30 30 CI RA Finland Sweden Denmark G 30 28 30 G 31 30 II2H3B P Nothing G 20 20 G 25 25 I2E Nothing Belgium G 30 28 30 G 31 37 I3 Nothing G 20 20 G 25 20 CI G 20 or G 31 20 G 30 or G 31 50 CI RA G 30 50 G 25 20 II2ELL3B P CI RA G 20 20 G...

Page 35: ...G 25 20 25 1 250 19 311 131 250 gas G 25 20 1 280 19 311 131 280 G 25 25 1 260 19 311 131 260 G P L G 30 or G 31 28 30 1 165 22 5 311 131 165 30 or 37 G 30 or G 31 50 1 145 19 311 131 145 G 31 50 1 155 19 311 131 155 Pilot burner Natural G 20 G 25 20 25 1 41 310 273 gas G 25 20 1 45 311 172 G P L G 30 or G 31 28 30 1 30 311 171 30 or 37 G 30 or G 31 50 1 25 310 274 Idle screw Natural G 20 G 25 20 ...

Page 36: ... G 31 50 2 145 19 311 131 145 G 31 50 2 155 19 311 131 155 Pilot burner Natural G 20 G 25 20 25 1 Réf A26 gas G 25 20 1 Réf A26 G P L G 30 or G 31 28 30 1 40 132 886 30 or 37 G 30 or G 31 50 1 Réf K14 310 091 Idle screw Natural G 20 G 25 20 25 1 230 310 284 adjustment gas G 25 20 1 300 310 194 G P L G 30 or G 31 28 30 or 50 1 115 310 178 30 or 37 or 50 Configuration valid only for 50 mbar propane ...

Page 37: ...1 110 105 6 5 311 131 110 105 G 31 37 BP 6 95 5 311 131 95 BS G D 1 1 110 105 5 311 131 110 105 G 30 50 BP 6 85 4 5 311 131 85 BS G D 1 1 90 90 4 5 311 131 900 90 G 31 50 BP 6 90 4 311 131 90 BS G D 1 1 100 95 4 311 131 100 95 Pilot burner Natural G 20 G 25 20 25 1 41 310 273 gas G 25 20 1 45 311 172 G P L G 30 or G 31 28 30 or 50 1 25 310 274 30 or 37 or 50 Idle screw Natural G 20 G 25 20 25 1 29...