10. Lace the fuser heater wire in the rear side
through the aperture of the right fuser unit
and pull it out.
11. Refit the right and left fuser unit.
Figure 1-5-88
12. Connect front and rear positive terminal to
thermstats.
Cautions
Insert the terminal all the way into the unit.
Put the slack of electric wire toward the front
side of the machine.
Push each terminal and heater wire into the
housing so as not to exceed the height of
the rib of the fuser unit (because they may
come in contact with the machine frame at
the time of installation of the machine).
Figure 1-5-89
Fuser heater wire
Fuser heater
wire
Right fuser unit
Right fuser unit
Positive terminal
Fuser heater wire
Rib
Rib
To front
To front
Positive terminal
Fuser heater wire