4. Programming
496792
51
Continuous Sounder (Command 25)
Option 0 of this Command makes the internal sounder follow the external bell
delay and duration times. Option 1 makes the internal sounder continue after
the external bell times out.
Local Sounder Delay on Entry (Command 26)
This Command controls the time at which local sounders operate in response
to an entry alarm.
Option 1 (default) introduces a delay to allow silent communications when an
entry alarm is triggered (required by some police forces). The option is only
valid under the following conditions:
Alarm abort off (Command 36).
Bell delay not zero (Command 41).
Dual Ply off (Command 86).
Alarm Confirm (Command 89) disabled.
If you enable option 1 the control unit starts the local sounders at the same
time as the external sounders if an intruder strays from the entry route, or the
entry time expires, and after any bell delay.
Option 0 causes the control unit to start the internal sounders immediately an
intruder strays from the entry route or the entry time expires.
Exit Fault External Sounders (Command 27)
When programmed with option 0 the system operates the internal sounders if
the user tries to exit while a zone is still violated (for example a door is not
shut). When programmed with option 1 the system operates the external
sounders as well as the internal sounders.
Status Display (Command 28)
Use option 1 of this Command if you do not wish to show keypad displays
permanently. The keypad displays “Level Set” for 180 seconds after the user
sets the system and then reverts back to the time and date display. Use this
option when installing a system in the U.K.
When set to option 0 the keypad displays “Level Set” the whole time that the
alarm system is set.
Use option 2 to make the keypad display “Level Set” for 30 seconds after any
event. Note that if you use this option the
s
and
f
LEDs also operate for
only 30 seconds.
Entry Alarm Delay Time (Command 29)
Note: Disable Alarm Confirmation (Command 89) to gain access to this Command.