4. Programming
40
496792
To change:
Key-in:
Notes
Default
Test Internal Sounder
94
Y
Internal sounders operate, press
X
or
Y
to
end test.
Test Keypad Sounder
95
Y
Keypad sounders operate, press
X
or
Y
to
end test.
Engineer Walk Test*
97
Y
Zn indication and chime operate when
* See “5. Testing”
cct open
Y
(Clear) End walk test
Load Defaults
98
Y
1
Y
Load defaults
Leave Programming
99
Y
Communications Programming
Call Mode
101
Y
0 Disabled
Y
1
Single
2
Alternate
3
Dual
Reporting Type
103
Y
0 Fast format
Y
1
Contact ID
2
SIA I
3
SIA II
4
SIA 3
5
Extended SIA 3
Static Test Call
105
Y
A (or B) nn
Y
00 Static off
Y
nn is the time in hours
A nn Static call at nn hours, 01 to 24 max.
nn is the day of the month
B nn Static on day nn, 01 to 24 max.
Line Fail Response
106
Y
0 Disabled
1
Audible
Y
2
Silent
Dynamic Testing
108
Y
0 Dynamic off
Y
1
Dynamic on
Three Way Calling (UK)
109
Y
0 Three way off
Y
1
Three way on
Download Mode
110
Y
n
Y
Where n is one of:
0
Local PC (9752 only)
1
Remote PC
Y
Rings To Answer
112
Y
0 3 rings
Downloading option
1
5 rings
Y
2
7 rings
3
10 rings
4
15 rings
5
255 rings