4. Programming
42
496792
To change:
Key-in:
Notes
Default
Radio Zone Supervision
128
Y
0
Full alarm (all sounders plus comms)
Y
Fail Response
1
Internal, external and keypad sounder
2
Keypad sounders
3
Comms only
4
Inhibit set
Telecommand requires
129
Y
0
Yes
Y
Entry Door to Unset
1
No
Extended Report Mode
131
Y
0
Basic
Y
1
Summary
2
Intermediate
3
Full
Send Tamper as Burglary
132
Y
0
Off
Y
1
On
CID Report Restorals
143
Y
0 Mode Basic
1
Mode Basic + Restore
Y
Plug by Comms Output 1
151
Y
nn
Where nn is one of the following:
00
Not Used
11
AC Fail
01
Fire (Y)
12
Tamper Alarm
02
PA
13
Open
03
Burglar
14
Close
04
Open/Close
15
Zone Omitted
05
Alarm Abort
16
Medical
06
Technical Alarm
17
Key-Box
07
Alarm Confirmation
18
Anti-Mask
08
RF Low Battery
19
Smoke Detector
09
RF Supervision Loss
20
Comms Acknowledge
10
Jamming
21
Battery Fault
Plug by Comms Output 2
152
Y
Default 02 PA
See Command 151
Plug by Comms Output 3
153
Y
Default 03 Burglar
See Command 151
Plug by Comms Output 4
154
Y
Default 04 Open/Close See Command 151
Plug by Comms Output 5
155
Y
Default 15 Zone OmittedSee Command 151
Plug by Comms Output 6
156
Y
Default 05 Alarm Abort See Command 151
Plug by Comms Output 7
157
Y
Default 07 Confirm
See Command 151
Plug by Comms Output 8
158
Y
Default 06 Technical
See Command 151