4. Programming
496792
35
To change:
Key-in:
Notes
Default
Zone Configuration
21
Y
0
Close Circuit 4 wire
Y
1
Fully Supervised Loop
LS Chime Output
22
Y
n
Loudspeaker chime volume
0 = Off ( Keypad only)
1=low, 9=max
5
RedCare Reset
23
Y
0
Off
Y
1
On
Show Panel Account Name 24
Y
(keypad displays name)
X
Return to programming mode
Internal Sounder
25
Y
0
LS Timed (Follows external bell)
Y
1
Continuous
Sounder Delay on Entry
26
Y
0
Bell Delay off
1
Bell Delay on
Y
Exit Fault External Sounder 27
Y
0
Internal
Y
1
Local
Status Display
28
Y
0
Panel status visible all the time
Y
1
Panel status hidden 180s after setting
2
Display for 30 s on valid access code entry
Entry Alarm Delay Time
29
Y
0
Delay off
1
Delay on
PA Response
30
Y
0
Audible
Y
1
Silent
Zone Tamper Reset
31
Y
0
Engineer reset off
Y
1
Engineer reset on
System Reset
33
Y
0
Eng reset off
Y
1
Eng reset on
PA Reset
34
Y
0
PA cust reset
Y
1
PA eng reset
First Circuit Lockout
35
Y
0
Lock out on
Y
1
Re-arm
Alarm Abort
36
Y
0
Abort off
Y
1
Abort on
Day Tamper Comms
37
Y
0
Day Tamper off
Y
1
Day Tamper on
System Tamper Reset
38
Y
0
Customer Reset
1
Engineer Reset
Y
Summary of Contents for 9752
Page 1: ...HARDWIRED CONTROL PANELS INSTALLATION AND PROGRAMMING GUIDE...
Page 6: ...iv 496792 Contents...
Page 12: ...6 496792 1 Introduction...
Page 18: ...12 496792 2 Technical Description...
Page 38: ...32 496792 3 Installation...
Page 90: ...84 496792 5 Testing...
Page 95: ...Notes...