4. Programming
496792
41
To change:
Key-in:
Notes
Default
Answer On One Ring
113
Y
0 One ring off
Y
Downloading option
1
One ring on
Access Mode
114
Y
0 Callback off (Attended)
Y
1
Callback on
2
Callback any (Unattended)
Communicator Tel No 1
115
YY
Maximum 31 digits
Communicator Tel No 2
116
YY
Maximum 31 digits
Account No 1
117
YY
Maximum 6 digits
Downloader Tel No 1
118
YY
Maximum 31 digits
Downloader Tel No 2
119
YY
Maximum 31 digits
Enable Downldr Tel No 3
120
Y
0
Downloader Tel No 3 Off
1
Downloader Tel No 3 enabled.
Fast Format Channels
121
Y
a
Y
b
Y
For built in Communicator
a is the channel number 1 to 8
b is one of the following:
00
Not Used
11
AC Fail
01
Fire
(default Ch 1)
12
Tamper Alarm
02
PA
(default Ch 2)
13
Open
03
Burglar
(default Ch 3)
14
Close
04
Open/Close
(
default Ch 4)
15
Zone Omitted (default Ch 5)
05
Alarm Abort (default Ch 6)
16
Medical
06
Technical Alarm (default Ch 8)
17
Key-Box
07
Alarm Confirmation (dlt Ch 7)
18
Anti-Mask
08
RF Low Battery
19
Smoke Detector
09
RF Supervision Loss
10
Jamming
Comms Acknowledge
122
Y
0
Off
Y
1
On
Note: Options are only available if Command 126 is set to option
X
1 (Ireland).
Restoral Reporting
123
Y
0 Restore off
Y
1
Restore on
Reverse Open/Closed
124
Y
0
Disabled
1
Reverse codes
No Close if CCT Omitted
125
Y
0
Disabled
(9752 only)
1
No close sent if more than one cct omitted.
Language
126
Y
nn
nn = Language, one of:
0 = English
(
Y
)
3 = Portuguese
6 = German
9 = Danish
1 = Italian
4 = Dutch
7 = Norwegian
2 = Spanish
5 = French
8 = Swedish
Summary of Contents for 9752
Page 1: ...HARDWIRED CONTROL PANELS INSTALLATION AND PROGRAMMING GUIDE...
Page 6: ...iv 496792 Contents...
Page 12: ...6 496792 1 Introduction...
Page 18: ...12 496792 2 Technical Description...
Page 38: ...32 496792 3 Installation...
Page 90: ...84 496792 5 Testing...
Page 95: ...Notes...