4. Programming
496792
75
INTERMEDIATE
Event
SIA Code
CID Code
BURG RESTORE
BR
130‡
DOWNLOAD SUCCESS
RS
412
EXPANDER MISSING RESTORE
TR
137‡
EXPANDER TAMPER RESTORE
TR
137‡
GLOBAL TAMPER RESTORE
TR
137‡
JAMMING
XQ
380
KEYBOX CLOSED
UR
150
KEYBOX OPEN
UA
150
LID TAMP RESTORE
TR
137‡
PASSWORD DEFAULTS LOADED
RH
-
SENSOR TAMPER RESTORE
TR
137‡
SOUNDER TAMPER RESTORE
TR
137‡
SUPERVISION FAIL
BZ
381
SYS TAMPER RESTORE
TR
137‡
TAMPER KEYPAD RESTORE
TR
-
TX BATTERY TROUBLE
XT
384
FULL
Event
SIA Code
CID Code
AC LOST
AT
301
AC RESTORE
AR
301‡
AUX RESTORE
YQ
-
AUX TROUBLE
YP
-
BATT MISSING
YM
311
BATT RESTORED
YR
311‡
LOW BATT
YT
311
LOW BATT RESTORE
YR
311‡
TD (Time and day) RESET
JT
625
TELCO1 FAULT
LT
351
TELCO1 FAULT RESTORE
LR
-
USER CODE CHANGED
JV
-
USER CODE DELETED
JX
-
Figure 24. SIA Telegram Reports
Send Tamp as Burg (Command 132)
DD243: 2002 states that alarm signals and confirmation signals must be
transmitted using certain codes. In some case these codes do not conform to
Cooper Security Ltd’s implementation of the SIA standard. In addition, some
ARC’s experience problems if a control unit sends “restore” messages using
SIA. The ARC interprets “restores” as “user restores”. When using SIA
reporting Command 132 allows you to program the control unit to send
tampers as alarm, and disable the transmission of “restore” messages.
Option 0
(Default) The control unit sends all SIA messages as specified in
Command 131.
Option 1
For full alarm response the control unit sends tampers as burglary
(BA) and sends Contact ID 130 in place of Contact ID 137. In
addition the control unit does not send: FR (fire restoral), PR
(panic restoral), UR (technical restoral), BR (burglary restoral) or
TR (tamper restoral).
Contact ID Options (Command 143)
If you selected Contact ID in Command 103 then use Command 143 to
select the types of contact ID messages that will be sent.
Option 0
Mode Basic, comprises all the messages with numbers in the
“CID Code” column of Fig 24, with the exception of those marked
with an “‡”.
Option 1
Mode Basic + Restore. With this option the system sends all the
messages with numbers in the “CID Code” column of Fig 24.