BRIEF GUIDE TO CONTROL AND SET UP THE SYSTEM
66
SMS-text
Command
USERx Ca Mb
Record of sender phone number from which this SMS was send and causes of alarm/
service notifications (a, b) for user x
USERx Ca Mb
''+……''
Record of phone number specified in this SMS and causes of alarm/service
notifications (a, b) for user x
AUTOCHECK a b c
Setting of system automatic account balance check:
where
a
– position number in GSM-operator’s reply text on account balance request,
which corresponds to balance integral part (1-10. 0 - automatic account check
function is off)
b
– critical account balance level (1 - 255. default setting – 25)
с
– time period in which system should check account balance (1 - 24 hours. default
setting - 6)
ATTENTION!
Any SMS which do not start with PIN-code will be ignored by system. System won’t respond to all SMS
during the following 2 minutes.
List of alarm/service messages’ causes (a, b)
Alarm/service message cause
a value
(digits after C)
b value
(digits after M)
Alarm «Call» button is pressed
0
0
Ignition input is active. PIN-code fitting attempt. Power supply
12V has disappeared.
1
1
Door/hood/trunk pin switch actuated. External siren input is
active
2
2
Additional/shock/motion/inclination/glass brake sensor was
actuated
3
3
Universal pin switch was actuated. Engine autostart is failed
5
5
Battery is discharged. System account balance is less than
critical one
6
GSM-network signal is disappeared/appeared
7
System disarming
8
8
System arming
9
9
ATTENTION!
If SMS do not contain letters C and M system will save previous list of alarm/service notifications (before
this SMS).
9.2.2 System hardware-controlled settings
SMS-text
Setting/Command
CONFIG?
Current system hardware settings request
TURBOTIMER x y
Selection of system operation time in turbotimer mode (x = 0 – 255 min, y = 0 – 255
sec ); on default x=0, y=0
STARTTIMER x
Selection of delay time of engine start check (x = 4 -1000 sec. default setting - 60)
ARMTIMER x
Selection of delay time of pin switches scanning (x = 0 – 255 sec, default setting - 15)
REARM 1
System automatic rearming function activation
REARM 0