SYSTEM PROGRAMMING AND SETTING
6.1.12 Setting built-in inclination/motion sensor
System has 10 levels of built-in inclination/motion sensor adjustment (1 - 9). 1 – the highest sensitivity
(sense the smallest inclination angle), 9 – the lowest sensitivity (sense the biggest inclination angle). Default
set ting – 0 (inclination sensor is deactivated).
To adjust inclination sensor enter the following command in SMS text (see item 2.3):
SENSOR x y
where
x
= 0 - all sensors of system (shock, inclination/motion, external) are deactivated
x
= 1 - all sensors of system are activated
y
= (0-9) – inclination/motion sensor level. 0 – sensor is deactivated
Factory settings: x-1, y-0
After receipt of SMS with this command GSM-system will send report with confirmation of deactivation/
activation of all sensors and inclination/motion sensors’ level adjustment:
SENSOR OFF, d.naklona y
or
SENSOR OFF, d.naklona OFF
or
SENSOR ON, d.naklona y
or
SENSOR ON, d.naklona OFF
Note
Command without x,y specifying can be also used for request of current status of sensors and inclination
sensor settings status.
6.2 System hardware-controlled settings using SMS
ATTENTION!
In order to change hardware-controlled settings of GSM-system install safety jumper into main unit
(see sub-item 7.4.1).
6.2.1 Current hardware-controlled settings request
To request current system hardware settings enter the following command in SMS text (see item 2.3):
CONFIG?
After receipt of SMS with this command GSM-system will send report with the list of settings of inputs,
outputs, universal timer channels, turbotimer parameters, etc:
CONFIG: ...
6.2.2 Setting system inputs
System has 8 universal adjustable inputs.
Universal inputs can work both with normal closed and normal opened circuits (programmed) and also with
circuits of any polarity (programmed).
When adjusting GSM-system universal inputs, specify input signal polarity, circuit type (closed on arming
or opened). If input is used as alarm, specify type of car alarm circuit for determination of proper alarming cause
notification. When connecting to impulse circuits specify also minimum close/open input time.
While adjusting the universal inputs of GSM-system first of all determine how the GSM-system will be
controlled - by car regular central lock, additional security system, only by cell phone or using other method. If it
necessary determine under the selected type of system control in the settings of the inputs IN1, IN2, IN3, IN4
and IN8 special functions (f = 0): arm, prohibition of arm, disarm, sign of arm or permission of arm/disarm. If it
is necessary, you can also use the disarm prohibition input (blue (green) wire of 4-pin connector of system main
unit (only for model Convoy iGSM-005 CAN - see sub-item 7.4.1)). Usually, there is no need to use all these inputs
to control the system.
If it is planned to use in the system «Immobilizer» mode (see item 3.4), an exception of trunk terminal switch
from the arm while remote opening of its lock and simultaneous work of the system with the additional engine
auto start module (for example, Convoy ARS-300), it is also necessary to specify special functions (f =0) for
inputs IN5, IN6 and IN8.
Typical ovariants of connecting the system universal inputs with special functions - see sub-item 7.4.4,
7.4.5, 7.4.6.