SYSTEM COMPONENTS INSTALL ATION AND CONNECTION
50
7.4.4 Connection diagram of factory central lock control (main unit 18-pin connector)
“Stopsignal”
+12V
87
86
30
85
green
IN1
IN2
IN3
IN4
IN5
IN6
IN7
IN8
OUT4
Door pin switch (/+)
Trunk pin switch ()
Disarming confirmation button (/+)
Parking lights (+)
Arming/disarming permission
Blocking bypass ()
grey
digital bus
greenred
To blackred
Convoy ARS300
To turn lights
(+/)
yellowred
whitered
yellowblack
bluered
blueblack
greenblack
redblack
red
red
black
blackred
blackwhite
white
black
blue
white
(2А)
(+12V)
Hood pin switch ()
(+12V)
Main system
power 12V
Reserve system
power supply +12V
+
+
Regular CL drive (+/)
To starter solenoid
Blocking
87
87А
86
NC
NO
+12V
START
30
85
Additional channel
№3
To greenblack
Convoy ARS 300
()
Universal
output №3 ()
OUT3
OUT2
OUT1
OUT5
OUT6
Autostart START
Additional channel №2
To bluered
Convoy ARS 300
()
Universal
output №2 ()
or
or
or
Regular CL drive (+/)
Regular CL
closing
To green (blue)
GPSM 003
Regular CL
opening
To trunk lock
drive (+)
Ignition
(+12V)
yellow
Service ignition (+)
To whitered
Convoy ARS300
External alarm (+)
Siren (+)
To blue black
Convoy ARS300
and
(2А)
brown
10А
Car body
Service button
input ()
+12V
or
Note
GSM-system wires connections when operating with remote engine start module Convoy ARS-300 are
also shown on the diagram.