Gsm Advanced Manual - 9
99
9
3.2 SMS control
Any incoming SMS will be parsed to find up to 5 commands that will be recognized either
uppercase, lowercase and mixed, also embedded within alien text.
Remote control commands are available to registered users and some special system
commands are reserved to supervisors.
Users registered in both groups can issue SMS made by mixed remote and system commands.
3.2.1 REMOTE CONTROL COMMANDS
The following default commands, available to any registered user, can be modified to any other
following specification [§ 12].
S
Set AuxO output permanently ON
on
Set temperature control ON
Having setpoint=0, the output will turn on regardless ambient temperature.
Having probe failure, output will turn on regardless ambient temperature.
Optional trailer text
ddhhmm
can define the activation time
output will set to ON until specified time has been elapsed
dd
00 to 99 days
hh
00 to 23 hours
mm
00 to 59 minutes
If a blackout occur the output will not be set to ON at further power on.
R
Reset AuxO OFF
off
Reset temperature control OFF
Having setpoint=0, the output will turn off regardless ambient temperature.
Having probe failure, output will turn off regardless ambient temperature.
M
Set AuxO ON and LATCH (set again at further power on)
run
Set temperature control ON and LATCH (set again at further power on)
Having setpoint=0, the output will turn on regardless ambient temperature.
Having probe failure, output will turn on regardless ambient temperature.
Optional trailer text
ddMMyyhhmm
can be used to define the date
of output reset to OFF
dd
day
MM
month
yy
year
hh
hour
mm
minute
If a blackout occur the output will be set again to ON until scheduled date has been
reached. Output status is recovered ONLY once the synchronization of internal clock
has been performed successfully.
Issuing an output reset command the output will be released and scheduled time
deleted.
D
A Status SMS will be sent back
B
A ringback will be sent back once incoming SMS has been processed
Example:
S000830 nonsense text D run1409061830
turn ON Aux output for 8 hours and 30 minutes, send back a status SMS
turn ON and latch temperature control until September 14
th
2006 - 6:30 PM