Gsm Advanced Manual - 16
16
16
16
6.2 Add Conditioned users
Up to 250 users can be stored into the device Phonebook by means of GsmSuite programming
software. Any supervisor can also add users issuing an SMS:
+1,INDEX,TEL,NAME,TICKET,ENABLE,DISABLE,,,LEADER
6.2.1 INDEX
The position assigned inside the internal phonebook, starting from index 1 up to 250.
Omitting index, the user will be stored at first available position.
6.2.2 TEL
The telephone number that will be recognized. Number should be stored in international format
(including Country code). Up to 20 characters available.
6.2.3 NAME
The name of the user associated with the telephone number. Up to 14 characters available.
6.2.4 TICKET
It’s possible to define a number of allowable operations for conditional users, specifying a
number in the range 1÷999. Every command issued by the user will decrease the available
tickets, once the ticket available is zero the user cannot issue commands.
It’s possible to specify the optional index for an interactive message (0÷9, stored at group 8) that
will be sent at each operation, remaining ticket will be reported at the end of this SMS.
ttti ttt
available tickets 0÷999
i
identifier of interactive message 0÷9
6.2.5 ENABLE
It’s possible to enable a user belonging to group 1 starting from a specific date and time.
It’s possible to specify the optional index for an interactive message (0÷9, stored at group 8) that
will be sent once the user has been enabled.
ddmmyyhhmmi dd
day of the month, 01÷31
mm
month 01÷12
yy
year 00÷99 (2000÷2099)
hh
hour 00÷23
mm
minute 00÷59
i
identifier of interactive message 0÷9
6.2.6 DISABLE
It’s possible to disable a user belonging to group 1 at specific date and time.
Once period is expired the user will be removed from the Phonebook.
It’s possible to specify the optional index for an interactive message (0÷9, stored at group 8) that
will be sent once the user has been disabled.
ddmmyyhhmmi dd
day of the month, 01÷31
mm
month 01÷12
yy
year 00÷99 (2000÷2099)
hh
hour 00÷23
mm
minute 00÷59
i
idenftifier of interactive message 0÷9
6.2.6 LEADER
It’s possible to specify a leader text to be placed at beginning of interactive message, this could