Gsm Advanced Manual - 29
29
29
29
12.4 Reset temperature control off
A specific SMS command is available to deactivate temperature control (or directly turn off
working in on/off mode and regulator is disabled).
Default settings can be modified by means of GsmSuite or by supervisors issuing the following
SMS:
+4,254,,SmsCommand,,,,,LogText
12.4.1 SmsCommand
The text that will be associated to this command when received within an SMS coming from
authorized users. Must be a single word, up to 14 characters long.
Default is
off
12.4.2 LogText
This text will be included in the log string issued when trace is active.
Default is
reg off request
12.4.3 Example
+4,254,9,boileroff,,,,,,boiler deactivation
Set SMS command to “off” and log text “pump release”
12.4.4 Confirmation
Once Phonebook edit has been successfully done, device will send back an SMS specifying
assigned index, name and 7 markers to specify which fields are defined (
*
) and which don’t (
-
):
254,boileroff,*----*