3 Hardware Setup
PT-E731, PT-E731S, PT-E731H, PT-E731HS User’s Manual
19
(4) Tighten the screws of mounting fittings to fix PT-E. (The tightening torque range is 6.3 to
8.4kgf
·
cm.)
Figure 3.4. Fixing PT-E (PT-E731/PT-E731S/PT-E731H/PT-E731HS)
Installation Requirements
Be sure that the ambient temperature is within the range specified in the installation environment
requirement by making space between the product and device that generates heat or exhaust air.
Installed angle which is recommended 30
°
Basically mount main body of PT-E in vertical direction. PT-E must be mounted with a tilt of +/- 30° or
less from vertical when mounting it diagonally.
Figure 3.5. Installed angle which is recommended
CAUTION
Do not mount the main body of PT-E upward or downward.