background image

 OPERATING INSTRUCTIONS

GSM-GPS Tracker with Alarm Function
„GX103+GPS“

Item No. 66 24 93

Version 07/12

Summary of Contents for GX103+GPS

Page 1: ...OPERATING INSTRUCTIONS GSM GPS Tracker with Alarm Function GX103 GPS Item No 66 24 93 Version 07 12...

Page 2: ...ing the PIN Code Command PIN 14 2 Changing the Device Name Command NAME 14 3 Setting the Language Command LANGUAGE 15 4 Setting Time and Date Command TIME 15 5 Administration of Phone Book Command TEL...

Page 3: ...Conformity DOC 33 18 Technical Data 34 a GSM GPS Tracker 34 b USB Mains Adapter 34 1 Introduction Dear Customer Thank you for purchasing this product This product complies with the statutory national...

Page 4: ...The customer is responsible for application of the product in accordance with the law Conrad Electronic does not assume any responsibility liability exceeding application of the product as described...

Page 5: ...s damaged do not touch it Danger to life from electric shock First switch off the mains voltage for the mains socket to which the USB mains adapter is connected switch off the corresponding circuit br...

Page 6: ...used to determine and monitor GPS zones Area GeoFence i e places where the product may be present The product is secured against manipulation with an internal battery This product is not a common pho...

Page 7: ...s are available for this LED flashes blue Current GPS position determined correctly LED is lit blue GPS position not determined or determinable LED off GPS module is in sleeper mode switched off The G...

Page 8: ...o the PC a driver is needed for the virtual COM port so that the product can be configured via USB and a firmware update performed The required software and firmware files are available online at www...

Page 9: ...when connecting the device to a USB mains adapter the GPS receiver remains active at all times The remaining functions are not affected by any USB connection c Notes on Use There is no prescribed usa...

Page 10: ...having to switch off in spite of USB connection to protect the internal battery against deep discharge If such behaviour occurs during the test wait for a few minutes until the battery was sufficient...

Page 11: ...nspected at the product site with a separate mobile phone If the LED flashes red there is an error when connecting to the GSM provider or the PIN number is incorrect In this case the device must be re...

Page 12: ...safety the PIN number must be changed under all circumstances after commissioning of the product This is described in more detail in the chapter corresponding to the command Introduction to the Comma...

Page 13: ...ill overwrite the previous settings After every text message command the device will return a test message answer to confirm the programming if the PIN in the text message command was correct and the...

Page 14: ...The PIN code always has 4 figures When the PIN code is lost lost or forgotten the product can be reset to factory settings see chapter Factory Settings All programming will be lost when resetting The...

Page 15: ...is stored in the text message independently of when the text message was sent or received Various functions also require the current time and date SET TIME hh mm dd mm yy 1513 Hour Minute Day Month Ye...

Page 16: ...333 1513 After sending the command SET TEL a text message answer with a list of saved phone numbers is generated GX103_GPS 1 08 Alarm SMS1 49111 SMS2 49222 SMS3 49333 SMS4 empty SMS5 empty SMS6 empty...

Page 17: ...product it may be of disadvantage that the product draws attention by an alarm sound The unauthorised person would be able to destroy the product to prevent notification Therefore the alarm sound can...

Page 18: ...gs are set in the default settings on level 5 This setting can be changed in a range of 0 lowest stage to 9 highest stage The following command must be used for this SET AUDIO SPK MIC MELODY RING Vol...

Page 19: ...E Acountdown beep sounds When it ends the product is armed A time can be set from 1 60 s Timer Time_disable If an alarm is triggered in the active alarm mode ALARM ENABLE e g by motion detector you ca...

Page 20: ...r The microphone can be used to monitor e g a room or area Every sensor s sensitivity can be set The best sensitivity settings depend on many factors such as installation site car body connection obje...

Page 21: ...C Once the USB supply voltage fails this can be configured as reason for the alarm The following command is needed for this Activation of the USB monitoring SET USB 1513 Stop monitoring RESET USB 1513...

Page 22: ...t be pushed again the LED in the button signals the current sensor status The LED will switch off again after no more than 30 s in any case The corresponding sensor configuration is used for the next...

Page 23: ...ust be sent again Alternatively the function can be reset by RESET RECALL 1513 The current status can be determined with the following command TEST RECALL 1513 2 Reaction at Incoming Call INCALL Any c...

Page 24: ...ake changes Any permitted call is accepted at once without notification The external speaker is deactivated during the call This permits listening to what happens inside Listening to and eavesdropping...

Page 25: ...the customer indirectly by leaving out this information message This command must be transmitted to activate the command SET ALIVE DAYs 1513 Days number of days between messages 1 30 0 off The followi...

Page 26: ...nother setting when using external accessories This information is also included in the operating instructions for the accessories Generally the following rule applies The following command is always...

Page 27: ...ave a higher deviation This is connected with the GPS signal that requires correction data for high accuracy They are overlain with the GPS signal and are usually transmitted once every 30 minutes a G...

Page 28: ...link For GoogleMaps only the map image is displayed but no control options This makes it possible to display this page on older mobile phones as well The linked to OpenStreetMap org website requires...

Page 29: ...s here When the memory flows over the oldest value is overwritten The current status as well as indication of the existing and free memory points and estimation of the maximum recording time are retur...

Page 30: ...tude 1 latitude 2 longitude 2 1513 Latitude 1 upper threshold towards North Latitude 2 upper threshold towards South Longitude 1 left threshold towards West Longitude 2 right threshold towards East Th...

Page 31: ...tes all saved zones RESET GPSZONE ALL 1513 Deleting one zone The following command deletes a single zone RESET GPSZONE Zone no 1513 Checking a programmed zone To check the programmed zones in the spec...

Page 32: ...n In this period you will not receive any new messages on alarm situation changes Within this period however every user is able to check his parameters The following command resets the settings to fac...

Page 33: ...ccording to the relevant statutory regulations b Batteries and Rechargeable Batteries You as the end user are required by law Battery Ordinance to return all used batteries rechargeable batteries Disp...

Page 34: ...Watt at DCS1800 GPS Sirius 1612R Channels 68 Cold start 29 s Warm start 28 s Hot start 1 s Sensitivity 165dBm Vibration sensor LIS331DL Min sensitivity approx 100 mg Motion sensor AMN11112 Opening ang...

Page 35: ...35...

Page 36: ...ction by any method e g photocopy microfilming or the capture in electronic data processing systems require the prior written approval by the editor Reprinting also in part is prohibited These operati...

Reviews: