background image

+-++

CatM1 NB loT Asset GPS Tracker

NT07E

User manual

Summary of Contents for NT07E

Page 1: ... CatM1 NB loT Asset GPS Tracker NT07E User manual ...

Page 2: ...t will be added to the new version of this manual KINGWO will improve or update the products or procedures described in the manual at any time If there is a description of the product in the manual that does not match the actual product the actual product shall prevail KINGWO has the final interpretation rights of this manual ...

Page 3: ...2 1 1 Appearance PART 01 Product Overview ...

Page 4: ... 1 2 LED status LED type Event Status Cellular LED Red Network connecting Fast flash Network connected Slow flash Module error Solid on GPS LED Green GPS position Solid on LBS position 0 5 seconds on 0 5 seconds off Wifi Position 2 seconds on 2 seconds off No position Off 1 3 Product features summary Built in 8100mah batteries it can last 5 years if upload data once a day Multiple work modes Regul...

Page 5: ...nsitivity 107dBm 850 900MHz 106dBm 1800 1900MHz Output power Class 4 2W 850 900MHz Class 1 1W 1800 1900MHz GPRS data GPRS Class 10 Mobile Station Class B GPS Channels 50 Sensitivity 147dBm Position accuracy 5 10m Accuracy 5m CEP Cold start 27s Hot start 1s Processor ST Motion sensor DA260 Wifi position Wifi 4 0 Power Battery Disposable Lithium ion battery and 3 6V 8100mAh and ultra low discharge r...

Page 6: ...e ping the data packets information includes GPS status longitude and latitude cellular signal Strength satellite numbers battery level etc there are multiple track modes available from the device below is the explanation for work mode priorities Track mode Warehouse Regular mode Clock mode Week mode Motion and static mode The work mode which is equal can be replaced by each other and the last con...

Page 7: ...ackend and upload packet according to the configured intervals 3 Under track mode if the SIM card loosen network register failure or server failure happens device will turn off celluar and GPS for 30 minutes and then attempt connection however if the removal alarm triggered during this period it will immediately attempt a connection 3 GPS will wake up if motion detected in power save mode 2 1 2 Wa...

Page 8: ...ad interval Unit Minutes Value range 5 43200minutes 2 30 days Exit storage mode STORAGE 0 Note Default setting is wake up each 1440 minutes 24 hours Fixed upload mode can t be wake up by motion 2 1 4 Clock mode Configuration SMS Command Set clock mode MODE 4 N T1 T2 TN For example MODE 4 3 0800 1400 2100 T1 TN is time point format is HHMM for example 0800 indicates 08 00 Delete clock mode and retu...

Page 9: ... Indicates upload interval in motion status is 60 minutes upload interval in static status is 300 minutes motion alarm on T1 Upload interval in motion status value 5 43200 minutes T2 Upload interval in static status value 5 43200 minutes or set clock mode format HH MM A Motion Alarm on 0 Motion Alarm off Note Device can t be wake up by vibration while in motion mode Device can be wake up by vibrat...

Page 10: ...ck those hotspots info and saved into the packet that will be uploaded after the backend receives Wi Fi information it will interpret the WIFI info and acquire the current location from the Wi Fi database The default setting is WIFI priority once it detects WIFI Hotspot it will upload WIFI info only and do not use GPS if WIFI is not detected it will use GPS to position Kindly reminder To use Wi Fi...

Page 11: ...ill automatic send this command to make sure the commands is properly received 2 8 Strong Magnetic and waterproof function NT07E is with built in with super strong magnet that can firmly stick the device to the metal surface it is easy to install and conceal and the device is with waterproof function which can be installed on any assets that are outdoors 2 9 Position Priority 2 9 1 GPS WIFI LBS Tu...

Page 12: ...0 AGPS When the device successfully registers on network AGPS is available to speed up the position speed and improve the position accuracy 2 11 History data upload and Delete function Command BLIND A A 1 OFF A 0 ON Clear command CLR BLIND More than 128 positions can be saved the blind zone data read is first in first out 2 12 Early sleep mode In order to reduce the waste of power the device will ...

Page 13: ...s 2 2 14 Connection timeout Normally the maximum duration time of each wake up of the device is 15 minutes 2 15 Network and Bands lock Command SEARCH P BandNBiot BandCAT M1 P Network priority P 1 Lock GSM P 2 Nbiot Priority CAT M Second GSM final P 3 CAT M Priority GSM Second NB OFF Defaulted P 4 Lock CAT M P 5 Nbiot Priority GSM Second CAT M OFF P 6 CAT M Priority NB Second GSM OFF P 7 Nbiot Prio...

Page 14: ...larm and report the alarm info to the backend or preset phone number Command FALL A A 3 Turn on the removal alarm and only report data once as defaulted A 2 Turn on the removal alarm tracking for 15 minutes once every 300 seconds A 1 Turn off the removal alarm function A 0 Turn on the removal alarm function tracking for 60 minutes once every 60 seconds 3 2 Motion alarm The motion is in static mode...

Page 15: ...n and followed the positioning packets it will report a WIFI failure alarm 3 5 G sensor failure alarm If Gsensor I2C initialization failed it will report motion sensor failure with position packets 3 6 Collision Alarm Command COLLISION A Value Range 0 8000mg When the acceleration change value exceeds A the device immediately wakes up and reports a collision alarm please note collision alarm won t ...

Page 16: ...ce and note down the SIM card number 4 1 2 Main unit power on After installing the SIM card turn the battery switch to the ON position When the red light starts to blink indicating that the device is powered on 4 1 3 Major parameter setting by SMS or SSCOM tool SMS list APN apn user pwd Set APN User name and password For example APN CMNET internet internet APN CMNET Username internet Password inte...

Page 17: ...point in time such as 0830 for 08 30 in the morning FALL A A 3 Switch on removal alarm do not track defalut value A 2 Switch on removal alarm track 15 mins 300 seconds once A 1 Switch off removal alarm A 0 Swtich on removal alarm track 60 minutes 60 seconds once UTC TTTT Set time zone unit minute default UTC 8 00 STORAGE T Storage mode return interval default is 0 that is turn off t wake up time u...

Page 18: ...the tracker is fitted with a powerful magnet please the tracker directly on a metal surface Please do not put tracker in the metal environment which will affect the GPS signal Safety Information Don t dissemble the device by yourself Avoid strong humidity direct sunlight and high temperature Dont use on airplane It is better to put this side up while install the device ...

Page 19: ...d Contact us 86 0755 86704262 marketing kingwoiot com www itracksense com www kingwoiot com Room 301 302 3rd Floor Comprehensive Building Tsinghua Information Hi tech Park North Science Park Nanshan District Shenzhen China 518052 ...

Reviews: