The current collector is mounted onto the towing plate:
Fig. 127: Mount the PH current collector (Order No.: 081506…, 081507…, 081508…, 081509…) onto towing plate
Conductix-Wampfler recommends using the PE current collectors in assembly types 081506…,
081507…, 081508…, 081509…without cams, and the assembly types equipped with interchanging pro-
tection 081506…, 081507…, 081508…, 081509…with cams. Special towing plates with a slot at the PE
position are also provided for the assembly. In the case of older systems, a replacement for these types
must be considered.
Fig. 128: Mount the PE current collector onto the towing plate
Pos.
Description
1
Towing plate
2
PE current collector
A
Slot in towing plate
B
PE current collector cam
2
1
A
B