Operating Instructions
Single-pole Conductor Rail System
SingleFlexLine Program 0815
BAL0815-0002g-US
www.conductix.us
translated document
page 28 of 128
Fig. 14: Expansion module with 20 mm expansion gap
NOTE!
Expansion units reduce the system load capacity of the overall system!
See Section 3.1
Fig. 15: Air gap insulation section
Air gap insulation section
The air gap insulation sections are used for the electrical isola-
tion of the conductor rail. The air gap insulation section consists
of 2 opposing end caps and a connecting bar that is clipped over
the end caps and thus connects them. The air gap insulation
sections are available with and without a line feed option (see
Section 6.3.3.6).
Fig. 16: Current collector and current collector unit
Current collector
Current collector as a sliding electrical connection between con-
ductor rail and the mobile consumer; typically designed as a mul-
tiple-pole unit.