Operating Instructions
Single-pole Conductor Rail System
SingleFlexLine Program 0815
BAL0815-0002g-US
www.conductix.us
translated document
page 26 of 128
Fig. 8: Fixed point cap
Fixed point cap
For mechanical fixing of the conductor rail to the installation
structure. Use of mechanical fixing on expanding sections
with long systems.
1 = Insertion cam
2 = Fixed point cap
3 = Hanger clamp (screw on)
4 = Guideway profile
5 = Hanger clamp screw connection with cylinder screw and
hexagon nut M4
The fixed point caps must be used with a hanger clamp
screwed to the guideway profile.
Fig. 9: Screwable connector
Connector
For mechanically and electrically connecting the individual
rail sections (plug or quick-screw technology). The connect-
ors are easily accessible from the front of the conductor rail.
Each connection point is protected against contact by a plas-
tic connector cap.
NOTE:
The connector 081526-6 may only be used for closed
slip ring applications! In addition, the connector 081526-6
must not be reused and connected rail bends must not be
bent further.
Fig. 10: Connector line feed
Line feed
The line feed is supplied through a connector line feed or an
end cap line feed. A connector can be fed with a connector
line feed at any point where the connector is located. The
connection is established through crimping cable lugs for 1.5
mm
2
–10 mm
2
conductor cross-sections.
Another line feed option is via the end cap for a transfer or
insulation section (max. 6 mm
2
).
For phases, double insulated cables must be provided for
voltages > 48 V.
5
2
2
4
3
5
2
2
4
3