6.3.4
Mounting the current collector
Different current collectors are used for existing and new systems:
Le
ga
cy syst
em
s
Fig. 121: Single current collector (081506…, 081507…)
Tolerances in the X-axis
and Y-axis: ± 10 mm
1 = Strain relief (optional)
Number
of Poles
b
B
4
42 54
6
70 82
8
70 110
10
70 120
Le
ga
cy syst
em
s
Fig. 122: Double current collectors (081508…, 081509…)
Tolerances in the X-axis
and Y-axis: ± 10 mm
1 = Strain relief (optional)
Number
of Poles
b
B
4
42 54
6
70 82
8
70 110
10
70 120
NOTE!
If the cable package with the strain relief (1) cannot be used, it must be ensured that the connection
cables in the area directly behind the current collector are strain-relieved on site. No tensile forces and/or
twisting forces may be transmitted to the current collector head. In addition, the connection cables must
not be sharply kinked.
Conductix-Wampfler recommends using the PE current collectors in assembly types 081506…,
081507…, 081508…, 081509…without cams, and the assembly types equipped with interchanging pro-
tection 081506…, 081507…, 081508…, 081509…with cams. Special towing plates with a slot at the PE
position are also provided for the assembly. In the case of older systems, a replacement for these types
must be considered.