NOTE!
The insulating profile of the expansion module (Pos. 2) has a recess at each conductor
rail pole end (see Fig. 85) so that the clamping unit (Pos. 3) does not slide out of the con-
ductor bar and over the insulating profile (Pos. 2)!
Fig. 85: Recess in the insulating profile of the expansion module (Pos. 2)
Slide the clamping unit of the connector (Pos. 3) completely into each conductor rail pole of the next conductor rail (see Fig. 86).
Ensure that the clamping unit is fully seated in the conductor bar. The clamping unit must not slip over the insulating profile (see
Fig. 75) and the conductor rail must not shift backward (see Fig. 76).
Fig. 86: Slide clamping unit of the connector (Pos. 3) into each conductor rail pole