SMS-7000 Modem Protection Switch
M-2000-Multiplexer Utilization
Rev. 3
B–3
Table B-1. SMS-7000/M-2000 50-Pin to 37-Pin Interface Cable Pinouts
50-Pin
Signal Name
37-Pin
1
Shield
1
37
CH2 SDA
4
38
CH2 SDB
22
39
CH2 RDA
6
40
CH2 RDB
24
21
CH3 SDA
5
22
CH3 SDB
23
23
CH3 RDA
8
24
CH3 RDB
26
4
CH4 SDA
3
5
CH4 SDB
21
6
CH4 RDA
15
7
CH4 RDB
33
B.2 Operation
On the switch M&C Configuration menu, enable multiplexers by selecting YES on the
Multiplexer submenu for each modem with a multiplexer. Enter a unique address for
each multiplexer. Load all modems and set Operation mode to Auto. Refer to Table 5-1
for fault information. Refer to the M-2000 Multiplexer Installation and Operation
Manual for further operation information.
Note: To operate with the switch, the MUX must be configured with both transmit and
receive faults enabled (ON).
Summary of Contents for SMS-7000
Page 2: ......
Page 6: ......
Page 8: ......
Page 34: ...Introduction SMS 7000 Modem Protection Switch 1 14 Rev 3 This page is intentionally left blank...
Page 43: ...SMS 7000 Modem Protection Switch Installation Rev 3 2 9 Figure 2 1 Top Mount Installation...
Page 70: ...Installation SMS 7000 Modem Protection Switch 2 36 Rev 3 This page is intentionally left blank...
Page 76: ...Operation SMS 7000 Modem Protection Switch 3 6 Rev 3 This page is intentionally left blank...
Page 83: ...SMS 7000 Modem Protection Switch Operation Rev 3 3 13 This page is intentionally left blank...
Page 104: ...Operation SMS 7000 Modem Protection Switch 3 34 Rev 3 This page is intentionally left blank...
Page 148: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...