Remote Control Operation
SMS-7000 Modem Protection Switch
A–14
Rev. 3 Draft
Equipment
Fault Status
Summary
Command:
Response:
<add/EFS_'cr'
>add/EFS_'cr'
DATA_MODULE_1_xxx'cr'
DATA_MODULE_2_xxx'cr'
DATA_MODULE_3_xxx'cr'
DATA_MODULE_4_xxx'cr'
DATA_MODULE_5_xxx'cr'
DATA_MODULE_6_xxx'cr'
DATA_MODULE_7_xxx'cr'
DATA_MODULE_8_xxx'cr'
IF_MODULE_xxx'cr'
PS1_xxx'cr'
PS2_xxx'cr'
NVRAM_CLK_xxx'cr'
M&C_xxx'cr'
I2C_xxx'cr'
SFLT_xx'cr''lf']
Data Switch Module #1 (OK/FLT)
Data Switch Module #2 (OK/FLT)
Data Switch Module #3 (OK/FLT)
Data Switch Module #4 (OK/FLT)
Data Switch Module #5 (OK/FLT)
Data Switch Module #6 (OK/FLT)
Data Switch Module #7 (OK/FLT)
Data Switch Module #8 (OK/FLT)
IF Switch Module (OK/FLT)
Power Supply #1 (OK/FLT)
Power Supply #2 (OK/FLT)
NVRAM/Clock (OK/FLT)
M&C Controller (OK/FLT)
I2C Bus (OK/FLT)
Number of Stored Faults Logged (0 through 10)
M:N Switch
Fault Status
Summary
Command:
Response:
<add/MNF_'cr'
>add/MNF_'cr'
COM_FLT_xxxxxxxxByBy'cr'
MOD_CONFIG_FLT_xxxxxxxxByBy'c
r'
DMD_CONFIG_FLT_xxxxxxxByBy'cr'
NO_MOD_CONFIG_xxxxxxxxByBy'cr
'
NO_DMD_CONFIG_xxxxxxxxByBy'cr
'
NO_ADX_xxxxxxxByBy'cr'
NOT_ASSIGNED_xxxxxxxxByBy'cr'
MU_COM_FLT_xxxxxxxxByBy'cr'
NO_MU_ADX_xxxxxxxxByBy'cr'
DATA_MODULE_FLT_xxxxxxxx'cr'
IF_MODULE_FLT'cr'
PS1_FLT'cr'
PS2_FLT'cr
NVRAM_CLK_FLT'cr'
M&C_FLT'cr'
I2C_FLT'cr''lf']
Modem Communications Faults
Mod Config Verify Faults
Demod Config Verify Faults
No Mod Configuration Loaded
No Demod Configuration Loaded
No Address Specified for Modem
Prime Assignment Fault
Mux Communications Faults
No Address Specified for Multiplexer
Data Module Faults
IF Module Fault
Power Supply #1 Fault
Power Supply #2 Fault
NVRAM/Clock Fault
M&C Controller Fault
I2C Bus Fault
Where:
x = 1 to 8 (prime modem/data module number).
y = 1 or 2 (backup modem number).
Note: Fault status data is only returned if fault conditions
exist.
Bulk
Consol.
Status
Faults
Command:
Response:
<add/BCSF_'cr'
>add/BCSF_'a''b''c'...'y''z''aa''ab''ac''a
d'
'ae''cr''lf']
This command causes all modem fault status to be
returned. To reduce the length of the response, fault status
is embedded into the bit structure of the characters that are
returned. Faults are indicated by a binary 1 in the
designated bit position.
Character 'a': Modulator fault status character 1.
Bit 6 = 1 always.
Bit 5 = Prime modulator fault #1 fault.
Bit 4 = Prime modulator fault #2 fault.
Bit 3 = Prime modulator fault #3 fault.
Bit 2 = Prime modulator fault #4 fault.
Bit 1 = Prime modulator fault #5 fault.
Bit 0 = Prime modulator fault #6 fault.
Character 'b': Modulator fault status character 2.
Bit 6 = 1 always.
Bit 5 = Prime modulator #7 fault.
Bit 4 = Prime modulator #8 fault.
Bit 3 = Backup modulator #1 fault.
Bit 2 = Backup modulator #2 fault.
Bit 1 = Reserved.
Bit 0 = Reserved.
Summary of Contents for SMS-7000
Page 2: ......
Page 6: ......
Page 8: ......
Page 34: ...Introduction SMS 7000 Modem Protection Switch 1 14 Rev 3 This page is intentionally left blank...
Page 43: ...SMS 7000 Modem Protection Switch Installation Rev 3 2 9 Figure 2 1 Top Mount Installation...
Page 70: ...Installation SMS 7000 Modem Protection Switch 2 36 Rev 3 This page is intentionally left blank...
Page 76: ...Operation SMS 7000 Modem Protection Switch 3 6 Rev 3 This page is intentionally left blank...
Page 83: ...SMS 7000 Modem Protection Switch Operation Rev 3 3 13 This page is intentionally left blank...
Page 104: ...Operation SMS 7000 Modem Protection Switch 3 34 Rev 3 This page is intentionally left blank...
Page 148: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...