Installation
SMS-7000 Modem Protection Switch
2–34
Rev. 3
2.6.2.7
Unbalanced Data Ports
Unbalanced data ports on 75
Ω
BNC coax connectors contain G.703, D&I, and external
clock signals. These data ports also facilitate IBS, D&I, or IDR data. When selected from
the control panel, the Unbalanced External Clock replaces the external clock signals on
J1, J3, and J6. The pinouts are shown in Table 2-15.
C AU TIO N
When using the G.703 unbalanced data ports for other than IDR data, be
certain there is no connection to the J6 (EIA-422) or J1 (V.35) ports. When
using G.703 data, all data switch modules must have jumper JP1 in
EIA-422 position (with jumpers connecting the middle pin and the pin
closest to the front of the switch module).
Table 2-15. Unbalanced Data Connectors
Signal Name
Pin #
IBS
IDR
D&I
CP1
G.703 SD
G.703 SD
DDI
CP2
G.703 RD
G.703 RD
IDO
CP3
Open
Open
DDO
CP4
Open
Open
IDI
CP5
EXC
EXC
EXC
Summary of Contents for SMS-7000
Page 2: ......
Page 6: ......
Page 8: ......
Page 34: ...Introduction SMS 7000 Modem Protection Switch 1 14 Rev 3 This page is intentionally left blank...
Page 43: ...SMS 7000 Modem Protection Switch Installation Rev 3 2 9 Figure 2 1 Top Mount Installation...
Page 70: ...Installation SMS 7000 Modem Protection Switch 2 36 Rev 3 This page is intentionally left blank...
Page 76: ...Operation SMS 7000 Modem Protection Switch 3 6 Rev 3 This page is intentionally left blank...
Page 83: ...SMS 7000 Modem Protection Switch Operation Rev 3 3 13 This page is intentionally left blank...
Page 104: ...Operation SMS 7000 Modem Protection Switch 3 34 Rev 3 This page is intentionally left blank...
Page 148: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...