SMS-7000 Modem Protection Switch
Installation
Rev. 3
2–27
2.6.2.1
EIA-422/8 kbit/s Terrestrial Data (J6)
This data port is used for IBS-422 terrestrial data or IDR 8 kbit/s terrestrial overhead
data. The connector is a 37-pin female D, with one connector per channel (Table 2-9).
C AU TIO N
When using this port for IBS or no overhead data, be certain there is no
connection to the J1 (V.35) or J3 (G.703) ports. When using EIA-422 data,
all data switch modules must have jumper JP1 in EIA-422 position (with
jumpers connecting the middle pin and the pin closest to the front of the
switch module).
Table 2-9. EIA-422 Terrestrial Data Connectors (J6)
Signal Name
Pin #
IBS
IDR
D&I
1
SHIELD
SHIELD
2
3
RS422 TXO-A
8K TXO A
4
SD A
8K TXD A
5
ST A
8K TXC A
6
RD A
8K RXD A
C
7
RTS A
RTS A
A
8
RT A
8K RXC A
B
9
CTS A
CTS A
L
10
E
11
DM A
N/C
12
R
13
RR A
N/C
E
14
M
15
EXC A
8K RXO A
O
16
RS422 RXO A
N/C
V
17
TT A
N/C
E
18
D
19
GND
GND
20
GND
GND
21
RS422 TXO-B
8K TXO B
Summary of Contents for SMS-7000
Page 2: ......
Page 6: ......
Page 8: ......
Page 34: ...Introduction SMS 7000 Modem Protection Switch 1 14 Rev 3 This page is intentionally left blank...
Page 43: ...SMS 7000 Modem Protection Switch Installation Rev 3 2 9 Figure 2 1 Top Mount Installation...
Page 70: ...Installation SMS 7000 Modem Protection Switch 2 36 Rev 3 This page is intentionally left blank...
Page 76: ...Operation SMS 7000 Modem Protection Switch 3 6 Rev 3 This page is intentionally left blank...
Page 83: ...SMS 7000 Modem Protection Switch Operation Rev 3 3 13 This page is intentionally left blank...
Page 104: ...Operation SMS 7000 Modem Protection Switch 3 34 Rev 3 This page is intentionally left blank...
Page 148: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...