SMS-7000 Modem Protection Switch
Remote Control Operation
Rev. 3 Draft
A–9
Verify
Prime
Modem X
Command:
Response:
<add/VMC_x'cr'
>add/VMC_x'cr''lf']
Where: x = 1 or 8 (prime modem number).
Note: Status can be polled after operation by using the MNF_
command.
Verify All
Modems
Command:
Response:
<add/VMC_ALL'cr'
>add/VMC_ALL'cr''lf']
Notes:
1. This command will verify all active backup and prime
modem configurations match those stored in the switch.
2. Status can be polled after operation by using the MNF_
command.
A.3.4 Breakout
Drop and
Insert
G.703 Data
Command:
Response:
Status:
Response:
<add/DID_n_xxxxx'cr'
>add/DID_n_xxxxx'cr''lf']
<add/DID_n'cr'
>add/DID_n_xxxxx'cr''lf']
Where:
n = 1 to 8 (prime channel number).
xxxxx = BAL (Balanced) or UNBAL (Unbalanced).
External
Clock
Command:
Response:
Status:
Response:
<add/ECLK_n_xxxxx'cr'
>add/ECLK_n_xxxxx'cr''lf']
<add/ECLK_n'cr'
>add/ECLK_n_xxxxx'cr''lf']
Where:
n = 1 to 8 (prime channel number).
xxxxx = BAL (Balanced) or UNBAL (Unbalanced).
Insert Data
Input
Command:
Response:
Status:
Response:
<add/IDI_n_xxxx'cr'
>add/IDI_n_xxxx'cr''lf']
<add/IDI_n'cr'
>add/IDI_n_xxxx'cr''lf']
Where:
n = 1 to 8 (prime channel number).
xxxx = LOOP or NORM (for NORMAL).
A.3.5 System
Time of Day
Command:
Response:
Status:
Response:
<add/TIME_hh:mmxx'cr'
>add/TIME_hh:mmxx'cr''lf']
<add/TIME_'cr'
>add/TIME_hh:mmxx'cr''lf']
Where:
hh = 1 to 12 (hours).
mm = 00 to 59 (minutes).
xx = AM or PM.
Date
Command:
Response:
Status:
Response:
<add/DATE_mm/dd/yy'cr'
>add/DATE_mm/dd/yy'cr''lf']
<add/DATE_'cr'
>add/DATE_mm/dd/yy'cr''lf']
Where:
mm = 1 to 12 (month).
dd = 1 to 31 (day).
yy = 00 to 99 (year).
Modem
Control
Baud Rate
Command:
Response:
Status:
Response:
<add/MBR_mmmmm'cr'
>add/MBR_mmmmm'cr''lf']
<add/MBR_'cr'
>add/MBR_mmmmm'cr''lf']
Where: mmmmm = 9600 or 19200.
Note: Enter command in Manual mode only.
Remote
Operation
Command:
Response:
<add/REM_'cr'
>add/REM_'cr''lf']
Notes:
1. Configures the SMS-7000 for remote operation.
2. The SMS-7000 will respond to any status request at
any time. However, the SMS-7000 must be in Remote
mode to change configuration parameters remotely.
Clear
Stored
Faults
Command:
Response:
<add/CLSF_'cr'
>add/CLSF_'cr''lf']
This command is used to clear all stored faults logged by the
SMS-7000.
Summary of Contents for SMS-7000
Page 2: ......
Page 6: ......
Page 8: ......
Page 34: ...Introduction SMS 7000 Modem Protection Switch 1 14 Rev 3 This page is intentionally left blank...
Page 43: ...SMS 7000 Modem Protection Switch Installation Rev 3 2 9 Figure 2 1 Top Mount Installation...
Page 70: ...Installation SMS 7000 Modem Protection Switch 2 36 Rev 3 This page is intentionally left blank...
Page 76: ...Operation SMS 7000 Modem Protection Switch 3 6 Rev 3 This page is intentionally left blank...
Page 83: ...SMS 7000 Modem Protection Switch Operation Rev 3 3 13 This page is intentionally left blank...
Page 104: ...Operation SMS 7000 Modem Protection Switch 3 34 Rev 3 This page is intentionally left blank...
Page 148: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...