SMS-7000 Modem Protection Switch
Remote Control Operation
Rev. 3 Draft
A–19
Bit 0 = Reserved.
Character 'ai': Prime #7 system fault status character 3.
Bit 6 = 1 always.
Bit 5 = Reserved.
Bit 4 = Reserved.
Bit 3 through Bit 0 = Binary representation (0 through 10)
of the number of Prime #7 system stored faults.
Character 'aj': Prime #8 system fault status character 1.
Bit 6 = 1 always.
Bit 5 = Prime modem communications failure fault.
Bit 4 = Prime modulator configuration verify error fault.
Bit 3 = Prime demodulator configuration verify error fault.
Bit 2 = No address for prime fault.
Bit 1 = No prime modulator configuration loaded fault.
Bit 0 = No prime demodulator configuration loaded fault.
Character 'ak': Prime #8 system fault status character 2.
Bit 6 = 1 always.
Bit 5 = Prime not assigned to backup fault.
Bit 4 = Prime multiplexer communications failure fault.
Bit 3 = No address for prime multiplexer fault.
Bit 2 = Reserved.
Bit 1 = Reserved.
Bit 0 = Reserved.
Character 'al': Prime #8 system fault status character 3.
Bit 6 = 1 always.
Bit 5 = Reserved.
Bit 4 = Reserved.
Bit 3 through Bit 0 = Binary representation (0 through 10)
of the number of Prime #8 system stored faults.
Character 'am': Equipment fault status character 1.
Bit 6 = 1 always.
Bit 5 = Data Switch Module #1 fault.
Bit 4 = Data Switch Module #2 fault.
Bit 3 = Data Switch Module #3 fault.
Bit 2 = Data Switch Module #4 fault.
Bit 1 = Data Switch Module #5 fault.
Bit 0 = Data Switch Module #6 fault.
Character 'an': Equipment fault status character 2.
Bit 6 = 1 always.
Bit 5 = Data Switch module #7 fault.
Bit 4 = Data Switch module #8 fault.
Bit 3 = IF Switch Module fault.
Bit 2 = Power Supply #1 fault.
Bit 1 = Power Supply #2 fault.
Bit 0 = NVRAM/Clock fault.
Character 'ao': Equipment fault status character 3.
Bit 6 = 1 always.
Bit 5 = M&C Controller fault.
Bit 4 = I2C fault.
Bit 3 through Bit 0 = Binary representation (0 through 10)
of the number of equipment stored faults.
Summary of Contents for SMS-7000
Page 2: ......
Page 6: ......
Page 8: ......
Page 34: ...Introduction SMS 7000 Modem Protection Switch 1 14 Rev 3 This page is intentionally left blank...
Page 43: ...SMS 7000 Modem Protection Switch Installation Rev 3 2 9 Figure 2 1 Top Mount Installation...
Page 70: ...Installation SMS 7000 Modem Protection Switch 2 36 Rev 3 This page is intentionally left blank...
Page 76: ...Operation SMS 7000 Modem Protection Switch 3 6 Rev 3 This page is intentionally left blank...
Page 83: ...SMS 7000 Modem Protection Switch Operation Rev 3 3 13 This page is intentionally left blank...
Page 104: ...Operation SMS 7000 Modem Protection Switch 3 34 Rev 3 This page is intentionally left blank...
Page 148: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...