Theory of Operation
SMS-7000 Modem Protection Switch
4–4
Rev. 3
4.1.4 Monitors
Three connectors provide switch status and fault information on the rear of the SCU
chassis (refer to Table 4-2).
Table 4-2. SCU Chassis Connectors
Switch Faults
J3
System, Equipment, and Stored Faults
9-pin D
Online Status
J6
Indicates whether prime modulators are on or offline
25-pin D
J5
Indicates whether prime demodulators are on or offline
25-pin D
Each set of fault output pins is isolated from internal switch electronics through single-
pole and double-throw relays. The three contacts of each relay are provided to the user
for direct application of visual and audio indicators. Relay contacts will support 1 mA of
continuous current at up to 30 VDC.
Normally open (NO) pins are connected to common (COM) for non-faulted indications
and online conditions. There is, however, one exception: the switch “COMMON
EQUIPMENT” fault has the normally closed (NC) contact connected to the common
(COM) for a no-fault condition (relay normally energized). This ensures that a fault is
indicated in the event of switch power loss.
Summary of Contents for SMS-7000
Page 2: ......
Page 6: ......
Page 8: ......
Page 34: ...Introduction SMS 7000 Modem Protection Switch 1 14 Rev 3 This page is intentionally left blank...
Page 43: ...SMS 7000 Modem Protection Switch Installation Rev 3 2 9 Figure 2 1 Top Mount Installation...
Page 70: ...Installation SMS 7000 Modem Protection Switch 2 36 Rev 3 This page is intentionally left blank...
Page 76: ...Operation SMS 7000 Modem Protection Switch 3 6 Rev 3 This page is intentionally left blank...
Page 83: ...SMS 7000 Modem Protection Switch Operation Rev 3 3 13 This page is intentionally left blank...
Page 104: ...Operation SMS 7000 Modem Protection Switch 3 34 Rev 3 This page is intentionally left blank...
Page 148: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...