Remote Control Operation
SMS-7000 Modem Protection Switch
A–8
Rev. 3 Draft
Prime
Demodulato
r On-line
Delay
Command:
Response:
Status:
Response:
<add/DD_x_yyy.y'cr'
>add/DD_x_yyy.y'cr''lf']
<add/DD_x'cr'
>add/DD_x_yyy.y'cr''lf']
Where:
x = 1 to 8 (prime modem demodulator number).
NONE, AUTO, or MANUAL.
yyy.y = 0.5 to 127.0 seconds (in 0.5 second increments).
Notes:
1. If AUTO is selected, switching occurs after a delay
period of 2.5 minutes.
2. If MANUAL is selected, enter the number of seconds for
the delay period.
3. Independent switching mode.
Prime
Modem On-
line Delay
Command:
Response:
Status:
Response:
<add/MD_x_yyy.y'cr'
>add/MD_x_yyy.y'cr''lf']
<add/MD_x'cr'
>add/MD_x_yyy.y'cr''lf']
Where:
x = 1 to 8 (prime modem number).
yyy.y = 0.5 to 127.0 seconds (in 0.5 second increments),
NONE, or AUTO.
Notes:
1. If AUTO is selected, the delay is two times the sweep
period.
2. Dependent switching mode.
Prime
Multiplexer
Unit
Attached
Command:
Response:
Status:
Response:
<add/MU_x_yyy'cr'
>add/MU_x_yyy'cr''lf']
<add/MU_x'cr'
>add/MU_x_yyy'cr''lf']
Where:
x = 1 to 8 (prime multiplexer number).
yyy = YES or NO.
Prime
Multiplexer
Unit
Address
Command:
Response:
Status:
Response:
<add/MUA_x_yyy'cr'
>add/MUA_x_yyy'cr''lf']
<add/MUA_x'cr'
>add/MUA_x_yyy'cr''lf']
Where:
x = 1 to 8 (prime multiplexer number).
yyy = 0 to 255 (Prime multiplexer address; 0 places prime
multiplexer out of service).
A.3.3 Switch
Load
Backup
Modem X
Command:
Response:
<add/LMC_Bx'cr'
>add/LMC_Bx'cr''lf']
Where: x = 1 or 2 (backup modem number).
Note: Status can be polled after operation by using the MNF_
or BCSF_ commands.
Load
Prime
Modem X
Command:
Response:
<add/LMC_x'cr'
>add/LMC_x'cr''lf']
Where: x = 1 or 8 (prime modem number).
Note: Status can be polled after operation by using the MNF_
command.
Load All
Modems
Command:
Response:
<add/LMC_ALL'cr'
>add/LMC_ALL'cr''lf']
Notes:
1. This command will load all active backup modem and
prime modem configurations.
2. Status can be polled after operation by using the MNF_
command.
Verify
Backup
Modem X
Command:
Response:
<add/VMC_Bx'cr'
>add/VMC_Bx'cr''lf']
Where: x = 1 or 2 (backup modem number).
Note: Status can be polled after operation by using the MNF_
command.
Summary of Contents for SMS-7000
Page 2: ......
Page 6: ......
Page 8: ......
Page 34: ...Introduction SMS 7000 Modem Protection Switch 1 14 Rev 3 This page is intentionally left blank...
Page 43: ...SMS 7000 Modem Protection Switch Installation Rev 3 2 9 Figure 2 1 Top Mount Installation...
Page 70: ...Installation SMS 7000 Modem Protection Switch 2 36 Rev 3 This page is intentionally left blank...
Page 76: ...Operation SMS 7000 Modem Protection Switch 3 6 Rev 3 This page is intentionally left blank...
Page 83: ...SMS 7000 Modem Protection Switch Operation Rev 3 3 13 This page is intentionally left blank...
Page 104: ...Operation SMS 7000 Modem Protection Switch 3 34 Rev 3 This page is intentionally left blank...
Page 148: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...