SDM-300L3 Satellite Modem
Revision 1
Remote Control Operation
MN/SDM300L3.IOM
A–9
RX 8PSK 2/3
IESS-310
Operation
Command:
Response:
Status:
Response:
<add/R310_xxx'cr'
>add/R310_xxx'cr''lf']
<add/R310_'cr'
>add/R310_xxx'cr''lf']
Where: xxx = ON or OFF.
RX IESS-315
Operation
Command:
Response:
Status:
Response:
<add/R315_xxx'cr'
>add/R315_xxx'cr''lf']
<add/R315_'cr'
>add/R315_xxx'cr''lf']
Where: xxx = ON or OFF.
LNB Power
Command:
Response:
Status:
Response:
<add/LNB_xxx'cr'
>add/LNB_xxx'cr''lf']
<add/LNB_'cr'
>add/LNB_xxx'cr''lf']
Where: xxx = ON or OFF.
LNB Voltage
Command:
Response:
Status:
Response:
<add/LNBV_xxx'cr'
>add/LNBV_xxx'cr''lf']
<add/LNBV_'cr'
>add/LNBV_xxx'cr''lf']
Where: xxx = 13,18, or 24 Volts
LNB
Reference
Enable
Command:
Response:
Status:
Response:
<add/LNBR_xxx'cr'
>add/LNBR_xxx'cr''lf']
<add/LNBR_'cr'
>add/LNBR_xxx'cr''lf']
Where: xxx = ON or OFF.
LNB Power
Monitor Low
Current
Threshold
Command:
Response:
Status:
Response:
<add/LNBL_xxx'cr'
>add/LNBL_xxx'cr''lf']
<add/LNBL_'cr'
>add/LNBL_xxx'cr''lf']
Where: xxx = 0 to 500 in 1 mA steps
LNB Power
Monitor High
Current
Threshold
Command:
Response:
Status:
Response:
<add/LNBH_xxx’cr’
>add/LNBH_xxx’cr’’lf’]
<add/LNBH_’cr’
>add/LNBH_xxx’cr’’lf’]
Where: xxx = 0 to 500 in 1 mA steps
A.3.3
Interface Configuration Commands
Interface
Transmit
Overhead
Type
Command:
Response:
Status:
Response:
<add/ITOT_xxxxx'cr'
>add/ITOT_xxxxx'cr''lf']
<add/ITOT_'cr'
>add/ITOT_xxxxx'cr''lf']
Where: xxxxx = NONE, IDR, IBS, DI, ASYNC,
AUPC, or FLEX.
Interface
Receive
Overhead
Type
Command:
Response:
Status:
Response:
<add/IROT_xxxxx'cr'
>add/IROT_xxxxx'cr''lf']
<add/IROT_'cr'
>add/IROT_xxxxx'cr''lf']
Where: xxxxx = NONE, IDR, IBS, DI, ASYNC,
AUPC, or FLEX.
TX Driver
Type
Command:
Response:
Status:
Response:
<add/TXDR_xxxxx'cr'
>add/TXDR_xxxxx'cr''lf']
<add/TXDR_'cr'
>add/TXDR_xxxxx'cr''lf']
Where: xxxxx = G703, V35, RS422, or RS232.
RX Driver
Type
Command:
Response:
Status:
Response:
<add/RXDR_xxxxx'cr'
>add/RXDR_xxxxx'cr''lf']
<add/RXDR_'cr'
>add/RXDR_xxxxx'cr''lf']
Where: xxxxx = G703, V35, RS422, or RS232.
Transmit
Clock
Command:
Response:
Status:
Response:
<add/TC_xxx'cr'
>add/TC_xxx'cr''lf']
<add/TC_'cr'
>add/TC_xxx'cr''lf']
Where: xxx = INT (internal SCT clock), EXT
(external TX terrestrial clock), REF (external
clock-reference frequency).
External
Clock-
Reference
Frequency
Command:
Response:
Status:
Response:
<add/ERF_nnnnn.n'cr'
>add/ERF_nnnnn.n'cr''lf']
<add/ERF_'cr'
>add/ERF_nnnnn.n'cr''lf']
Where: nnnnn.n = 8.0 to 10000.0 (external clock
frequency in kHz).
Transmit
Clock
Phase
Command:
Response:
Status:
Response:
<add/TCP_xxxx'cr'
>add/TCP_xxxx'cr''lf']
<add/TCP_'cr'
>add/TCP_xxxx'cr''lf']
Where: xxxx = NRM (normal clock phasing), INV
(inverted clock phasing), AUTO (automatic clock
phasing).