![Comtech EF Data SDM-300L3 Installation And Operation Manual Download Page 167](http://html1.mh-extra.com/html/comtech-ef-data/sdm-300l3/sdm-300l3_installation-and-operation-manual_2648475167.webp)
SDM-300L3 Satellite Modem
Revision 1
Front Panel Operation
MN/SDM300L3.IOM
4–99
FUNCTION SELECT: UTILITY: DEMODULATOR:
LNB
ALARM
-
LOW
LNB ALARM - LOW
0 mA
Status Only. Programmable within 0 to 500 mA, in 1 mA steps.
An alarm is generated whenever the LNB current falls below the programmed limit.
FUNCTION SELECT: UTILITY: DEMODULATOR:
LNB
ALARM
-
HIGH
LNB ALARM - HIGH
500 mA
Status Only. Programmable within 0 to 500 mA, in 1 mA steps. An alarm is generated
whenever the LNB current exceeds the programmed limit.
Note:
The low limit must be less than the high limit.
FUNCTION SELECT: UTILITY: DEMODULATOR:
RX SYMBOL RATE
RX SYMBOL RATE
64.000 Ksps
Status Only. Programmable with 4.800 to 2500 ksps. Provides the symbol rate
corresponding to the data rate, code rate(s), modulation, and overhead (framing)
programmed into the demodulator.