SDM-300L3 Satellite Modem
Revision 1
Installation/Upgrades
MN/SDM300L3.IOM
2–4
2.3
Software and Hardware Installation/Upgrades
2.3.1
Overhead Interface PCB Installation
The overhead interface PCB can be installed at the factory or in the field. The overhead
interface PCB is required to access certain options and functionality of the modem.
Observe the following:
•
If the overhead interface PCB is installed at the factory, then the 50-pin interface
relay card will be pre-installed or the G.703/ASYNC card.
•
If the overhead interface PCB is installed in the field, then one of four
connector/card combinations will have been shipped with the overhead interface
PCB.
2.3.1.1 Installation
CAUTION
This equipment contains parts and assemblies sensitive to damage by ESD.
Use ESD precautionary procedures when touching, removing, or inserting
PCBs.
The following tool is required to install the overhead interface PCB:
Description
Application
Phillips
Screwdriver
To remove and replace cross-point screws.
Use the following information to install the overhead interface PCB as a daughter card on
the main PCB. Refer to Figure 2-2 for the installation location of the overhead interface
daughter card.
CAUTION
Turn the power off before installation. High current VDC is present. Failure
to do so could result in damage to the modem components.
1. Turn off the modem and unplug the power supply.
2. Remove the rear panel retaining screws. Slide the modem assembly out from the
top cover assembly.
3. Install the overhead interface PCB, face down, onto the main PCB by mating the
male header connectors with the female header connectors in the position shown
in Figure 2-2.
4. Align the overhead interface PCB standoffs with the main PCB mounting holes.
Install the four mounting screws and washers.