SDM-300L3 Satellite Modem
Revision 1
Front Panel Operation
MN/SDM300L3.IOM
4–116
FUNCTION SELECT: UTILITY: SYSTEM: DEMO MODE
DEMO MODE
OFF
Displays the status of the Demo Mode as either On or Off. Enables all the FAST options
for the hardware installed for 1 hour.
CAUTION
Enabling Demo mode will set all parameters to factory default values.
FUNCTION
SELECT:
UTILITY: SYSTEM: EXT AGC: MAX PWR
EXT AGC:
MAX PWR
0.0 Volts
Sets the AGC voltage for a RX signal. The voltage range is 0.0 to 10.0V, in 0.5V steps.
Upon entry, the current external AGC voltage level is displayed. Press [
↑
] or [
↓
] to
increment or decrement the AGC voltage level in 0.5V steps. Press <ENTER> to execute
the change.
FUNCTION
SELECT:
UTILITY: SYSTEM: EXT AGC: MIN POWER
EXT AGC:
MIN PWR
10.0 Volts
Sets the AGC voltage for a RX signal. The voltage range is 0.0 to 10.0V, in 0.5V steps.
Upon entry, the current external AGC voltage level is displayed. Press [
↑
] or [
↓
] to
increment or decrement the AGC voltage level in 0.5V steps. Press <ENTER> to execute
the change.