![Comtech EF Data SDM-300L3 Installation And Operation Manual Download Page 33](http://html1.mh-extra.com/html/comtech-ef-data/sdm-300l3/sdm-300l3_installation-and-operation-manual_2648475033.webp)
SDM-300L3 Satellite Modem
Revision 1
Introduction
MN/SDM300L3.IOM
1–13
1.8.2
Functional Description
The M&C card is composed of the following subsections:
•
Microcontroller with Universal Asynchronous Receiver/Transmitter (UART)
•
Digital-to-Analog Converter (DAC)
•
Read Only Memory (ROM)
•
Analog-to-Digital Converter (ADC)
•
Read Access Memory (RAM)
•
Universal ASYNC
•
User Interface
•
Fault and Alarm Relays
MODEM
11 MHz
CLOCK
I C BUS
2
RAM AND
REAL
TIME
CLOCK
ROM
(M&C,
BULK,
BOOT)
FAULT
AND ALARM
RELAYS
MICRO-
CONTROLLER
DAC
ADC
EIA-232
OR
EIA-485
9-PIN
REMOTE
Figure 1-3
. M&C Block Diagram