Remote Control Operation
SDM-2020 Satellite Demodulator
B–16
Rev. 3
Demodulator
Stored Faults
Command:
Response:
<add/DSF_#'cr'
>add/DSF_# hh:mm:ss MM/DD/YY'cr'
MOD_xxx'cr'
CD_xxx'cr'
SYN_xxx'cr'
ICH_xxx'cr'
QCH_xxx'cr'
BERT_xxx'cr'
EBNT_xxx’cr’
CONF_xxx'cr''lf']
Demodulator Module (OK/FLT)
Carrier Detect (OK/FLT)
IF Synthesizer Lock (OK/FLT)
I Channel (OK/FLT)
Q Channel (OK/FLT)
BER Threshold (OK/FLT)
E
b
/N
0
Threshold (OK/FLT)
Configuration (OK/FLT)
Interface
Receive Side
Stored Faults
Command:
Response:
<add/IRSF_#'cr'
>add/IRSF_# hh:mm:ss MM/DD/YY'cr'
FSYN_xxx'cr'
RXD_xxx'cr'
PLL_xxx'cr'
FIFO_xxx'cr'
INT_xxx'cr'
2047_xxx’cr’
UNFL_xxx’cr’
OVFL_xxx’cr’
CLK_xxx’cr’
BUFF_xxx’cr’’If]
Frame Sync Lock (OK/FLT)
Data Stable/AIS (OK/FLT)
Receive Synth PLL Lock (OK/FLT)
Receive FIFO (OK/FLT)
Interface Module (OK/FLT)
2047 Pattern Lock Detect
Buffer Underflow (OK/FLT)
Buffer Overflow (OK/FLT)
Select Buffer Clock Activity (OK/FLT)
Buffer Full (OK/FLT)
Common
Equipment
Stored Faults
Command:
Response:
<add/CSF_#'cr'
>add/CSF_# hh:mm:ss MM/DD/YY'cr'
M&C_xxx'cr'
BAT_xxx'cr'
- 12_xxx'cr'
+12_xxx'cr'
+5_xxx'cr'
LNB_xxx'cr''lf']
Monitor & Control Module (OK/FLT)
Battery/Clock (OK/FLT)
-12V Power Supply (OK/FLT)
+12V Power Supply (OK/FLT)
+5V Power Supply (OK/FLT)
LNB (OK/FLT)
Reed-
Solomon
Unavailable
Seconds
Command:
Response:
<add/RSSF_#'cr'
>add/RSSF_# hh:mm:ss MM/DD/YY'cr'
UNA_xxx'cr''lf']
Unavailable Seconds (OK /FLT)
Bulk Consol.
Analog Status
Command:
Response:
<add/BCAS_'cr'
>add/BCAS_p1,p2,p3,p4'cr''lf']
Where: pn is the last parameter returned.
This command is similar to the 'BCS_' command but
returns demodulator analog parameters. Additional
status of new options and features will always be
appended to the end.
Where 'pn' = is the last parameter returned.
Parameter
Number
Parameter Name
(Command Reference)
Description
1
2
3
4
5
6
Receive Signal Level
(ref. 'RSL_' command).
Raw BER
(ref. 'RBER_' command).
Corrected BER
(ref. 'CBER_' command).
E
b
/N
0
(ref. 'EBN0_' command).
Interface Read Error Status
(ref. IRES_’command).
Buffer Fill Status
(ref. IBFS_’command).
p1 = xsnn.n, receive signal level in dBm.
p2 = xm.mE-ee.
p3 = xm.mE-ee.
p4 = xnn.n, EB/N0 in dB.
p5 = tttt_xm.mE-ee
p6 = nn%, buffer fill status
Summary of Contents for SDM-2020
Page 32: ...SDM 2020 Satellite Demodulator Introduction Rev 3 1 17 This page is intentionally left blank...
Page 35: ...SDM 2020 Satellite Demodulator Installation Rev 3 2 3 Figure 2 1 Typical Rack Installation...
Page 57: ...SDM 2020 Satellite Demodulator Operation Rev 3 3 13 This page is intentionally left blank...
Page 65: ...SDM 2020 Satellite Demodulator Operation Rev 3 3 21 This page is intentionally left blank...
Page 72: ...Operation SDM 2020 Satellite Demodulator 3 28 Rev 3 This page is intentionally left blank...
Page 75: ...SDM 2020 Satellite Demodulator Operation Rev 3 3 31 This page is intentionally left blank...
Page 92: ...Operation SDM 2020 Satellite Demodulator 3 48 Rev 3 This page is intentionally left blank...
Page 209: ...Fast Option SDM 2020 Satellite Demodulator C 6 Rev 3 This page is intentionally left blank...
Page 212: ...SDM 2020 Satellite Demodulator Glossary Rev 2 g 3 W Watt...
Page 213: ...Glossary SDM 2020 Satellite Demodulator g 4 Rev 3 This page is intentionally left blank...